Maintenance And Lubrication - JLG 400SC Service And Maintenance Manual

Hide thumbs Also See for 400SC:
Table of Contents

Advertisement

1.6 MAINTENANCE AND LUBRICATION

NOTE:
The following numbers correspond to those in Figure 1-1.
and Figure 1-2.
Table 1-9. Lubrication Specifications
KEY
MPG
Multipurpose Grease having a minimum dripping point of 350° F (177° C).
Excellent water resistance and adhesive qualities, and being of extreme
pressure type. (Timken OK 40 pounds minimum.)
EPGL
Extreme Pressure Gear Lube (oil) meeting API service classification GL-5 or
MIL-Spec MIL-L-2105
HO
Hydraulic Oil. API service classification GL-3, e.g. Standard UTTO fluid.
EO
Engine (crankcase). Gas (5W30)- API SN, -Arctic ACEA AI/BI, A5/B5 - API SM,
SL, SJ, EC, CF, CD - ILSAC GF-4. Diesel (15W40, 5W30 Arctic) - API CJ-4.
OGL
Open Gear Lubricant - Mobiltac 375 or equivalent.
LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION UNDER NORMAL
CONDITIONS. FOR MACHINES USED IN MULTI-SHIFT OPERATIONS AND/OR
EXPOSED TO HOSTILE ENVIRONMENTS OR CONDITIONS, LUBRICATION FREQUEN-
CIES MUST BE INCREASED ACCORDINGLY.
NOTE:
It is recommended as a good practice to replace all filters
at the same time.
1. Final Drive Hub
FILL
CHECK
Lube Point(s) - Level/Fill Plug
Capacity - 33.8 oz (1 L)(1/2 Full)
Lube - EPGL
Interval - Check level every 3 months or 150 hours of
operation; change every 2 years or 1200 hours of
operation
31215019
SPECIFICATIONS
SECTION 1 - SPECIFICATIONS
2. Hydraulic Return Filter
Interval - Change after first 50 hours and every
6 months or 300 hours thereafter or whenever
Charge Filter is replaced
3. Hydraulic Tank Breather
Interval - Change after first 50 hours and every 6 months
or 300 hours thereafter.
Comments - Remove wing nut and cover to replace.
Under certain conditions, it may be necessary to
replace on a more frequent basis.
1-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

460sjc

Table of Contents