SPN
3031
3219
3224
3224
3224
3224
3224
3226
3227
3234
3234
3234
3234
3234
3241
3248
3251
3251
3251
3251
3253
3253
3253
3253
3361
3361
3361
31215019
Table 3-5. Engine Fault Code Chart
FMI
2
Urea tank temperature outside of plausible thresholds
2
DFC SAE J1939 error No detail information
1
DFC for plausibility error Max for NOx sensor upstream of SCR Cat
2
DLC Error of CAN-Receive-Frame AT1IG1 NOX Sensor (SCR-system upstream cat; DPF-system downstream cat); length
of frame incorrect
2
DLC Error of CAN-Receive-Frame AT1IG1Vol NOX sensor
9
Timeout Error of CAN-Receive-Frame AT1IG1; NOX sensor upstream
9
Timeout Error of CAN-Receive-Frame AT1IG1Vol; NOX sensor
2
Nox feed back fault detection No detail information
2
DFC SAE J1939 error No detail information
2
DLC Error of CAN-Receive-Frame AT1O1 No detail information
2
DLC Error of CAN-Receive-Frame AT1O1Vol NOX
9
Timeout Error of CAN-Receive-Frame AT1OG1; NOX sensor (SCR-system downstream cat; DPF-system downstream
cat)
9
Timeout Error of CAN-Receive-Frame AT1OG1Vol
11
DFC for plausibility error Min for NOx sensor downstream of SCR Cat
0
Sensor SCR catalyst upstream temperature too high; plausibility error
4
Sensor error particle filter downstream temperature; signal range check low
0
Differential pressure DPF maximum value is exceeded
0
Differential pressure sensor across DPF exceeds warning high limit
1
Differential pressure DPF, pressure below lower shutoff threshold
1
Differential pressure DPF, pressure below lower warning threshold
2
Differential pressure DPF, plausibility error
2
Sensor differential pressure (DPF); plausibility error
3
Electrical error differential pressure B58 (DPF). (signal range check high)
4
Electrical error differential pressure (DPF). signal range check low.
3
DEF dosing valve; short circuit to battery on low side
3
DEF dosing valve; short circuit to battery or open load on high side
4
Urea dosing valve; short circuit to ground or open load on low side