SPN
729
898
975
975
975
1079
1080
1109
1136
1176
1176
1176
1176
1180
1180
1180
1180
1188
1188
1188
1188
1188
1188
1188
1188
1188
1188
1188
1188
3-90
Table 3-5. Engine Fault Code Chart
FMI
12
Cold start aid relay; over temperature error
9
Timeout Error of CAN-Receive-Frame TSC1TE; Set point
3
PWM-Signal Fan, short-circuit to plus
4
PWM-Signal Fan, open load or short circuit to ground
5
PWM-Signal Fan, Open load or short-circuit ground
13
Failure of sensor supply voltage 1
13
Failure of sensor supply voltage 2
2
Engine shut off demand ignored
0
Physical range check high for ECU temperature
0
Pressure sensor upstream turbine, Physical Range Check high
1
Pressure sensor upstream turbine, Physical Range Check low
3
Pressure sensor upstream turbine, signal range check (SRC) high
4
Pressure sensor upstream turbine, signal range check (SRC) low
0
Physical range check high for exhaust gas temperature upstream turbine
1
Physical range check low for exhaust gas temperature upstream turbine
3
Sensor error exhaust gas temperature upstream turbine; signal range check high
4
Sensor error exhaust gas temperature upstream turbine; signal range check low
0
Turbocharger wastegate, temperature critical high
2
Wastegate; status message from ECU missing
2
Turbocharger wastegate, CAN Error
3
Turbocharger wastegate, supply voltage above maximum threshold
4
Turbocharger wastegate, supply voltage below minimum threshold
6
Turbocharger wastegate, current above maximum threshold
7
Wastegate actuator; blocked
7
Turbocharger wastegate, mechanical blocking detected
7
Turbocharger wastegate, broken spring detected
11
Wastegate actuator; internal error
11
Wastegate actuator; EOL calibration not performed correctly
11
Wastegate actuator; over temperature (> 135°C)