Dip Switch Settings - BEA LZR-FLATSCAN W Manual

Safety sensor for automated windows
Table of Contents

Advertisement

4

DIP SWITCH SETTINGS

BACKGROUND
DIP 1
ANALYSIS
DIP 2
IMMUNITY
DIP 3
OBJECT SIZE
DIP 4
PINCH ZONE
ORANGE
5
TEACH-IN
Before launching a teach-in, make sure that:
- the detection field is free of objects
- the laser window protection cap is removed
- glass surfaces near the detection zone are covered
1.
To launch a teach-in, press the push button briefly or use the remote control (see below).
2.
The LED will flash red/green. Wait until it slowly flashes green.
3.
Position yourself in front of the detection field and strech out your arm in the bottom corner opposite to the
sensor in order to define the limit of the detection zone.
4.
The LED flashes red while calculating the detection zone. Once the LED is off, the teach-in is complete.
OR
75.0050.01 LZR-FLATSCAN W 20230908
ON
standard
"
3
4
ON
After changing a DIP switch, the orange LED flashes.
A LONG push on the push button confirms the settings.
OFF
ON: The sensor analyses the background located in
the detection field.
OFF
OFF: The sensor works with an uncovered zone of
min. 2 cm.
Switch to CRITICAL when external disturbances
critical
are likely to cause unwanted detections (increased
immunity).
2
"
1
See MIN. OBJECT SIZE setting
3
OFF
See OPTIONAL PINCH ZONE DIMENSIONS setting
Page 7 of 12