2
WIRING
12-24 VDC
1
COM
NO
2
COM
NC
2
1. If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and
rectifier as this will cause damage to the product.
2. Output status when sensor is operational (can be NO or NC). See page 10, OUTPUT CONFIGURATION.
3. If TEST is not used, apply 12 – 24 VDC to TEST wires (red and blue) to bypass.
3
ADJUSTING CURTAIN ANGLE
B
If necessary, adjust the tilt angle of the laser curtain by turning the tilt angle adjustment screw.
Page 6 of 12
GREEN
+
POWER SUPPLY
BROWN
-
YELLOW
OUTPUT RELAY 1
WHITE
VPB or Pinch Zone
PINK
OUTPUT RELAY 2
GRAY
Window Zone
RED
TEST
3
BLUE
PZ1
A
Create a loop with the wires of the power cable and
pass them through the notch as indicated.
Block the cable behind the notches. You can use the
flexible cable to guide the cable.
Cut the power cable to the right length, strip
the 8 wires and connect all wires as indicated.
The polarity of the power supply must be
respected!
Typical compliance with safety standards require
the test output to be connected and monitored via
controller.
A
B
75.0050.01 LZR-FLATSCAN W 20230908