5
TEACH-IN
FREE SHAPE TEACH-IN
You can also set the detection field by launching a "free shape" teach-in.
The shape and limit of the detection field is defined by a slow hand movement.
You have 30 seconds to define the detection field with your hand.
VIRTUAL PUSH BUTTONS (VPB)
After either one of the previous teach-ins, you can add virtual push buttons (max. 10) in the detection field. They
can be used as activation zones to open or close the window automatically:
1. When the green LED flashes, hold your hand in the desired position to learn the virtual push button.
2. When the LED flashes red to confirm the teach-in, remove your hand.
3. When the LED flashes green you can either learn another virtual push button or wait 10 seconds until the
end of the teach-in.
HOW TO REMOVE VPBs:
• Perform a VPB teach-in without putting your hand in the field.
• Perform a factory reset on the sensor.
Both of these options will remove ALL established virtual push buttons. You will have to perform new teach-ins for any that
you wish to remain for your application.
Launch a new teach-in each time the sensor position is changed or objects are added to or
changed in the detection zone.