SETUP / FACTORY RESET

STEP OUT OF THE INFRARED FIELD!
SETUP 1 (QUICK)
reference picture
SETUP 2 (ASSISTED)
test of full door cycle +
reference picture
FACTORY RESET

OVERVIEW OF SETTINGS

IR IMMUNITY
IR FREQUENCY
IR NUMBER
IR PRESENCE TIME
IR WIDTH
+
REDIRECTION
Unlock
+
complete reset to factory values
0
1
2
3
< 2.8 m
normal
high
low
A
B
service
1
2
mode
motion
15 s
30 s
1
WW
NN
WW
WW
safety
0 presence detection on safety input
safety
+
1 presence detection on safety and opening input
opening
factory value
Select parameter
+
+
4
5
6
> 2.8 m
higher highest
normal
Sensors mounted close to each other need a different frequency.
service mode = no IR detection during 15 minutes (maintenance).
this value excludes conformity of the door system to EN 16005 and DIN 18650.
2
5
10
min
min
min
min
NN
NN
WN
excludes conformity of the door system according to EN
16005 / DIN 18650 / BS 7036. IR Immunity on values 4 or 5 is
incompatible with IR presence time on value 0
Select value
2 s
4 s
7
8
9
≥ 2,8 m : 6 + 7 (EN 16005)
≥ 2,2 m : 6 + 7 (BS 7036)
high
min. value for DIN18650: 1 min
20 min 60 min infinite
min. value for EN16005: 30 s
Always additionally adjust
the arrow position on the
sensor with a screwdriver.
NN
NN
NW
Lock
5