Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation. DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair: 1.
5 Installation (Continued) Mount Sensor 1. Attach mounting template to center of door header as shown 2. Mount the sensor at a maximum height of 2” from the bottom line of above. Template should be 0” to 2” above bottom edge of header. the door operator.
6 Mechanical Adjustments Radar Motion Sensing Field: Width 6.4’ 3.2’ 3.2’ 6.4’ 6.4’ 3.2’ 3.2’ 6.4’ 3.2’ 3.2’ 6.4’ 6.4’ 9.6’ 9.6’ Wide Pattern Narrow Pattern 1. Insert the desired microwave antenna for a wide or narrow fi eld of detection. The optional narrow fi eld antenna is located in the slot behind the mounted antenna as shown.
7 Remote Control Adjustments Important Remote Control Adjustments Every programming session begins by unlocking the sensor. Thereafter a program setting may be altered by pressing the desired function key followed by the desired value for that function. When all programming is complete press the lock key twice to retain settings. Use the following as a guide: Unlock the sensor to enter into adjustment session (if no access code has been entered)
Page 6
7 Remote Control Adjustments (Continued) Important Remote Control Adjustments Rain Mode and Snow Mode: The Rain Mode or Snow Mode is designed to minimize the effect of heavy rain or snow on the Wizard’s auto learn requirements. When programmed for these modes, the mode will be enabled after the Wizard goes through two auto learn cycles with in six detections of the sensor.
8 Manual Set Up Without Remote Manual Set Up Set up of the Wizard may be accomplished by the use of two Wizard mounted programming buttons. The procedures below indicate how to program using these buttons. Program Buttons Briefl y press the right button and move away from the sensing To begin programming: patterns.
1. Adjust Infrared curtain as necessary. Use onds when attempting a set-up. and the sensor detects a door infl uence. of BEA’s Spotfi nder during this process is recommended. Door opens when it should close. 1. Relay Confi guration on wrong setting.
Page 9
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made. Never sacrifi ce the safe operation of the automatic door or gate for an incomplete solution.
Page 10
Addendum 1 SAFETY blue brown ACTIVATION green white POWER black POWER SAFETY blue brown ACTIVATION green white POWER black POWER Page 10 of 13 75.5122.05 20070427...
Page 11
Addendum 2 SAFETY blue brown ACTIVATION green white POWER black POWER SAFETY blue brown ACTIVATION green white POWER black POWER 75.5122.05 20070427 Page 11 of 13...
Page 12
Addendum 3 Page 12 of 13 75.5122.05 20070427...
Page 13
Addendum 4 75.5122.05 20070427 Page 13 of 13...