1 Description
2nd Radar Antenna
Radar Motion Sensor
Radar Antenna Clip
Radar Tilt Angle Indication
2 Specifi cations
DESCRIPTION
Supply voltage
Power frequency
Power consumption
Mounting height
• Standard
• High
SMR data input
Delay of the output activation after stimulation
3-color LED
Temperature range
Degree of protection
Product conformity
Dimensions
Weight
Housing material
Color of Housing
Cable length
DESCRIPTION
Technology
Detection fi eld (standard)
• Wide fi eld
• Narrow fi eld
75.5122.05 20070427
COMBINED RADAR ACTIVATION AND ACTIVE INFRARED SAFETY SENSOR
15°
30°
45°
SPECIFICATION
12 to 24 VAC / VDC: -5% to +10%
50 / 60 Hz
< 3 W
5'9" to 8'2"
8'2" to 13"
10 to 30 VDC
Transistor : < 1ms
• RED:
• GREEN:
• ORANGE: monitoring process
-30°F to +131°F
NEMA 3S / (IP54)
R&TTE 1999/5/EC & EMC 89/336/EEC BZT Germany, TÜV
10.4" x 2.2" x 1.9"
.55 lbs / 250 g
ABS & LURAN S
Anthracite gray (standard), aluminum or white fi nish
10' of 9-conductor cable
MOTION SENSOR
Microwave and microprocessor
Transmitter frequency: 24.125 GHz
Transmitter radiated power: <20 dBm EIRP
Transmitter power density: < 5 mW/cm²
13'0" W x 6'6" D
6'6" W x 8'2" D
presence detection
motion detection
PRESENCE SENSOR
Focused active infrared and
Self-monitored microprocessor
Spot diameter (standard): 4" max
Number of spots: 24 or 12 spots by curtain
Number of curtains: 2
6'6" W x 13.75" D
3'3" W x 13.75" D
WIZARD II SMR
USER'S GUIDE
Cover
Push Buttons
IR Presence Sensor
IR Prism
Main Connector
IR Curtain Adjustment Screw
Page 1 of 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WIZARD II SMR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BEA WIZARD II SMR

  • Page 1 WIZARD II SMR USER’S GUIDE COMBINED RADAR ACTIVATION AND ACTIVE INFRARED SAFETY SENSOR 1 Description Cover 2nd Radar Antenna Push Buttons Radar Motion Sensor IR Presence Sensor IR Prism Radar Antenna Clip Main Connector Radar Tilt Angle Indication 15° IR Curtain Adjustment Screw 30°...
  • Page 2: Pre-Installation Check

    Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation. DO NOT attempt any internal repair of the sensor. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair: 1.
  • Page 3: Mount Sensor

    5 Installation (Continued) Mount Sensor 1. Attach mounting template to center of door header as shown 2. Mount the sensor at a maximum height of 2” from the bottom line of above. Template should be 0” to 2” above bottom edge of header. the door operator.
  • Page 4: Mechanical Adjustments

    6 Mechanical Adjustments Radar Motion Sensing Field: Width 6.4’ 3.2’ 3.2’ 6.4’ 6.4’ 3.2’ 3.2’ 6.4’ 3.2’ 3.2’ 6.4’ 6.4’ 9.6’ 9.6’ Wide Pattern Narrow Pattern 1. Insert the desired microwave antenna for a wide or narrow fi eld of detection. The optional narrow fi eld antenna is located in the slot behind the mounted antenna as shown.
  • Page 5: Remote Control Adjustments

    7 Remote Control Adjustments Important Remote Control Adjustments Every programming session begins by unlocking the sensor. Thereafter a program setting may be altered by pressing the desired function key followed by the desired value for that function. When all programming is complete press the lock key twice to retain settings. Use the following as a guide: Unlock the sensor to enter into adjustment session (if no access code has been entered)
  • Page 6 7 Remote Control Adjustments (Continued) Important Remote Control Adjustments Rain Mode and Snow Mode: The Rain Mode or Snow Mode is designed to minimize the effect of heavy rain or snow on the Wizard’s auto learn requirements. When programmed for these modes, the mode will be enabled after the Wizard goes through two auto learn cycles with in six detections of the sensor.
  • Page 7: Manual Setup

    8 Manual Set Up Without Remote Manual Set Up Set up of the Wizard may be accomplished by the use of two Wizard mounted programming buttons. The procedures below indicate how to program using these buttons. Program Buttons Briefl y press the right button and move away from the sensing To begin programming: patterns.
  • Page 8: Power Up Procedures

    1. Adjust Infrared curtain as necessary. Use onds when attempting a set-up. and the sensor detects a door infl uence. of BEA’s Spotfi nder during this process is recommended. Door opens when it should close. 1. Relay Confi guration on wrong setting.
  • Page 9 Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made. Never sacrifi ce the safe operation of the automatic door or gate for an incomplete solution.
  • Page 10 Addendum 1 SAFETY blue brown ACTIVATION green white POWER black POWER SAFETY blue brown ACTIVATION green white POWER black POWER Page 10 of 13 75.5122.05 20070427...
  • Page 11 Addendum 2 SAFETY blue brown ACTIVATION green white POWER black POWER SAFETY blue brown ACTIVATION green white POWER black POWER 75.5122.05 20070427 Page 11 of 13...
  • Page 12 Addendum 3 Page 12 of 13 75.5122.05 20070427...
  • Page 13 Addendum 4 75.5122.05 20070427 Page 13 of 13...

Table of Contents