INSTALLATION (cont.)
Peripherals
IMPORTANT:
• All activation devices must be wired directly to hub.
• Logic modules must be activated by hub via Door Control Harness activation wires.

Home Switch

1
1
Install Home Switch at desired
location.
NOTES:
1. Any dry-contact Home Switch or auxiliary switch may be used and must be closed when door is closed.
2. For simultaneous pairs or dual-egress doors, two (2) Home Switches must be wired in series with orange wires of System
Harness plugged into hub.
On / Off / Hold Open Switch
1
Determine mounting location,
apply mounting template, drill
holes.
If using an existing On / Off / Hold Open switch, plug
On / Off / Hold Open Switch Jumper into hub port
labeled On / Off / Hold Open and wire-nut red and
black wires together, or if desired, splice existing
switch into jumper.
Page 6 of 16
Page 6 of 16
2a
For single doors, wire-nut white
Home Switch wires to orange
wires of System Harness plugged
into hub.
2
Route On / Off / Hold Open switch
harness and plug into hub port
labeled On / Off / Hold Open.
2b
For pairs of doors, wire-nut white
Home Switch wires in series to
orange wires of System Harness
plugged into hub.
FUNCTION
JUMPER WIRES
on
red jumped to black
hold open
black jumped to white
off
none