VLT HVAC Drive FC 102
Operating Guide
Type designation
Power losses and efficiency
Estimated power loss at rated maximum load [W]
Efficiency
(2)
The typical power loss is at normal load conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions).
1
Values are based on a typical motor efficiency. Lower efficiency motors also add to the power loss in the drive and conversely. If the switching fre-
quency is raised from nominal, the power losses may rise significantly. LCP and typical control card power consumptions are included. Further op-
tions and customer load may add up to 30 W to the losses. (Though typically only 4 W extra for a fully loaded control card or options for slot A or slot
B, each). Although measurements are made with state-of-the-art equipment, some measurement inaccuracy must be allowed for (±5%).
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency.
2
Table 53: Mains Supply 3x525–690 V AC, Normal Overload 110% for 1 Minute, P11K–P30K
Type designation
High/normal load
Typical shaft output at 550 V [kW]
Typical shaft output at 690 V [kW]
IP20/UL Open Type
IP21/UL Type 1
IP55/UL Type 12
Output current
Continuous (3x525–550 V) [A]
Intermittent (60 s overload) (3x525–550 V) [A]
Continuous (3x551–690 V) [A]
Intermittent (60 s overload) (3x551–690 V) [A]
Continuous kVA (550 V AC) [kVA]
Continuous kVA (690 V AC) [kVA]
Maximum input current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 690 V) [A]
Intermittent (60 s overload) (at 690 V) [A]
Maximum pre-fuses
[A]
(1)
SCCR
With mains disconnect [kA
rms
Without mains disconnect [kA
94 | Danfoss A/S © 2023.09
(1)
]
]
rms
P1K1
P1K5
P2K2
44
60
88
0.98
0.98
0.98
P11K
P15K
NO
NO
7.5
11
11
15
B4
B4
B2
B2
B2
B2
14
19
22.4
20.9
13
18
20.8
19.8
13.3
18.1
15.5
21.5
15
19.5
23.2
21.5
14.5
19.5
23.2
21.5
65 kA
65 kA
100 kA
100 kA
Specifications
P3K0
P4K0
P5K5
120
160
220
0.98
0.98
0.98
P18K
P22K
NO
NO
15
18.5
18.5
22
B4
B4
B2
B2
B2
B2
23
28
25.3
30.8
22
27
24.2
29.7
21.9
26.7
26.3
32.3
24
29
26.4
31.9
24
29
26.4
31.9
65 kA
65 kA
100 kA
100 kA
AQ267037536117en-000101 / 130R0083
P7K5
300
0.98
P30K
NO
22
30
B4
B2
B2
36
39.6
34
37.4
34.3
40.6
36
39.6
36
39.6
65 kA
100 kA

Advertisement