Danfoss VLT FC 102 Operating Manual page 89

Hvac drive
Hide thumbs Also See for VLT FC 102:
Table of Contents

Advertisement

VLT HVAC Drive FC 102
Operating Guide
Type designation
With mains disconnect [kA
rms
Without mains disconnect [kA
Power losses and efficiency
Estimated power loss at rated maximum load [W]
Efficiency
(3)
B3+4 and C3+4 may be converted to IP21 using a conversion kit.
1
The typical power loss is at normal load conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions).
2
Values are based on a typical motor efficiency. Lower efficiency motors also add to the power loss in the drive and vice versa. If the switching fre-
quency is raised from nominal, the power losses may rise significantly. LCP and typical control card power consumptions are included. Further op-
tions and customer load may add up to 30 W to the losses. (Though typically only 4 W extra for a fully-loaded control card or options for slot A or slot
B, each). Although measurements are made with state-of-the-art equipment, some measurement inaccuracy must be allowed for (±5%).
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency.
3
Table 48: Mains Supply 3x380–480 V AC and 3x220Y/380–277Y/480 V AC, Normal Overload 110% for 1 minute, P37K–P90K
Type designation
Typical shaft output [kW]
Typical shaft output at 460 V [hp]
IP20/UL Open Type
(1)
IP21/UL Type 1
IP55/UL Type 12
IP66/UL Type 4X
Output current
Continuous (3x380–439 V) [A]
Intermittent (3x380–439 V) [A]
Continuous (3x440–480 V) [A]
Intermittent (3x440–480 V) [A]
Continuous kVA (400 V AC) [kVA]
Continuous kVA (460 V AC) [kVA]
Maximum input current
Continuous (3x380–439 V) [A]
Intermittent (3x380–439 V) [A]
Continuous (3x440–480 V) [A]
Intermittent (3x440–480 V) [A]
SCCR
With mains disconnect [kA
rms
Without mains disconnect [kA
Danfoss A/S © 2023.09
]
]
rms
(2)
]
]
rms
P11K
P15K
P18K
65 kA
65 kA
65 kA
100 kA
100 kA
100 kA
278
392
465
0.98
0.98
0.98
P37K
P45K
P55K
37
45
55
50
60
75
B4
C3
C3
C1
C1
C1
C1
C1
C1
C1
C1
C1
73
90
106
80.3
99
117
65
80
105
71.5
88
116
50.6
62.4
73.4
51.8
63.7
83.7
66
82
96
72.6
90.2
106
59
73
95
64.9
80.3
105
65 kA
65 kA
10 kA
100 kA
100 kA
100 kA
AQ267037536117en-000101 / 130R0083 | 89
Specifications
P22K
P30K
65 kA
10 kA
100 kA
100 kA
525
698
0.98
0.98
P75K
P90K
75
90
100
125
C4
C4
C2
C2
C2
C2
C2
C2
147
177
162
195
130
160
143
176
102
123
104
128
133
161
146
177
118
145
130
160
65 kA
65 kA
100 kA
100 kA