5.8 DIAGNOSTICS
Flash messages are warning, error, or general information messages that are temporarily displayed in
response to certain key presses. These messages are intended to assist with navigation of the 469 messages
by explaining what has happened or by prompting the user to perform certain actions.
Table 5–5: FLASH MESSAGES
NEW SETPOINT HAS
BEEN STORED
INVALID PASSCODE
ENTERED!
SETPOINT ACCESS IS
NOW RESTRICTED
NO TRIPS OR ALARMS
TO RESET
PRESS [ENTER] TO ADD
DEFAULT MESSAGE
DEFAULT MESSAGES
6 TO 20 ARE ASSIGNED
TOP OF PAGE
5
[.] KEY IS USED TO
ADVANCE THE CURSOR
NEW SETPOINT HAS BEEN STORED: This message appear each time a setpoint has been altered and stored
as shown on the display.
ROUNDED SETPOINT HAS BEEN STORED: A setpoint value entered with the numeric keypad may be between
valid setpoint values. The 469 detects this condition and stores a value that has been rounded to the near-
est valid setpoint value. To find the valid range and step for a given setpoint, simply press
setpoint is being displayed.
OUT OF RANGE! ENTER: #### - ##### BY #: If an entered setpoint value that is outside of the acceptable
range of values, the 469 displays this message, substituting the proper values for that setpoint. An appro-
priate value may then be entered.
ACCESS DENIED, SHORT ACCESS SWITCH: In order to store any setpoint values, the access switch must be
shorted. If this message appears and it is necessary to change a setpoint, short access terminals C1 and
C2.
ACCESS DENIED, ENTER PASSCODE: The 469 has a passcode security feature. If that feature has been
enabled, not only do the access switch terminals have to be shorted, but the passcode must also be
entered. If the correct passcode has been lost or forgotten, contact the factory with the encrypted access
code. See Section 4.2.1: PASSCODE on page 4–4 for passcode features.
INVALID PASSCODE ENTERED: If an invalid passcode is entered for passcode security feature, this message
will flash on the display.
NEW PASSCODE HAS BEEN ACCEPTED: This message will appear as an acknowledge that the new passcode
has been accepted when changing the passcode for the passcode security feature.
PASSCODE SECURITY NOT ENABLED, ENTER 0: The passcode security feature is disabled whenever the pass-
code is zero (factory default). Any attempts to enter a passcode when the feature is disabled displays this
flash message. It prompts the user to enter 0 as the passcode. When this has been done, the feature may
be enabled by entering a non-zero passcode.
5-28
ROUNDED SETPOINT
OUT OF RANGE! ENTER:
HAS BEEN STORED
####-##### by #
NEW PASSCODE
PASSCODE SECURITY
HAS BEEN ACCEPTED
NOT ENABLED, ENTER 0
DATE ENTRY WAS
DATE ENTRY
NOT COMPLETE
OUT OF RANGE
RESET PERFORMED
ALL POSSIBLE RESETS
SUCCESSFULLY
HAVE BEEN PERFORMED
DEFAULT MESSAGE
DEFAULT MESSAGE
HAS BEEN ADDED
LIST IS FULL
INPUT FUNCTION
INVALID SERVICE
ALREADY ASSIGNED
CODE ENTERED
END OF PAGE
NO ALARMS ACTIVE
NO START BLOCKS
ACTIVE
469 Motor Management Relay
ACCESS DENIED,
SHORT ACCESS SWITCH
PLEASE ENTER A
NON-ZERO PASSCODE
TIME ENTRY WAS
NOT COMPLETE
CONDITION IS PRESENT
RESET NOT POSSIBLE
PRESS [ENTER] TO
REMOVE MESSAGE
KEY PRESSED IS
INVALID HERE
TOP OF LIST
END OF LIST
THIS FEATURE NOT
PROGRAMMED
5 ACTUAL VALUES

5.8.2 FLASH MESSAGES

ACCESS DENIED,
ENTER PASSCODE
SETPOINT ACCESS IS
NOW PERMITTED
TIME ENTRY
OUT OF RANGE
ARE YOU SURE? PRESS
[ENTER] TO VERIFY
DEFAULT MESSAGE
HAS BEEN REMOVED
DATA CLEARED
SUCCESSFULLY
MOTOR STARTING
SS1SS2SS3SS4SS5SS6SS