"Screed" set-up menu
Menu for setting up the basic screed settings and screed functions.
- (1) Display and adjustment parameters for "Delayed screed start" -
delay time (sec)
On swivelling the drive lever, the floating function is only activated once an adjusted
A
time has elapsed.
Setting range 0-10 sec.
A
- (2) Display and adjustment parameters for the central lubrication system
- (2.1): Extended lubrication interval
- (2.2): Standard lubrication interval
- (2.3): Shortened lubrication interval
If necessary, the lubrication interval has to be adjusted to the prevailing paving situ-
A
ation and to the material.
- (2.4): Function "Lubrication interval - manual start".
The lubrication function is started manually and runs for the selected interval.
A
Press again to cancel.
- (3) Info on screed type
The screed type is automatically recognised.
A
- (4) Info on screed heater
The gas / electric heater type is automatically recognised.
A
1
2
2.1
2.2
3
4
2.3
2.4
D 22 33