Item Designation
Levelling cylinder
61
adjustment
Raising/lowering
62
auger (o)
Brief description
Button with detent switch function and LED feedback:
- For manual actuation of the levelling cylinders when
the automatic levelling system is switched off.
- Switch OFF by pressing the button again
The corresponding switch on the remote control must
A
be switched to "Manual" for this function.
Levelling cylinder adjustment is carried out with the ad-
A
justment buttons in the displayed arrow direction.
This function is also activated when the remote control
A
is not connected!
Button with detent switch function and LED feedback:
- For hydraulic adjustment of the auger height.
- Switch OFF by pressing the button again.
The height can be read on the scales to the left and the
A
right of the auger crossbeam support.
Rule of thumb: Paving thickness plus 5 cm (2 inches)
equals the auger crossbeam height.
Actuate both relevant adjustment switches at the same
A
time as the auger crossbeam otherwise jams!
Auger adjustment is carried out with the adjustment but-
A
tons in the displayed arrow direction!
D 13 45