Figure 25
1. 2-socket electrical
connector—machine
harness (R
P
)
INSE
UMP
5.
Plug the 2 pin connector of the rinse-tank
pump harness into the 2-socket of the machine
harness labeled R
Positioning the Rinse-Pump Cover
Align the pump cover over the rinse-tank pump as
shown in
Figure
26.
Note:
Do not insert the tabs into the slots in the
saddle plate.
Figure 26
1. Rinse-pump cover
2. 2 pin connector (rinse-tank
pump harness)
P
(Figure
25).
INSE
UMP
2. Rinse-tank pump
6
Installing the Hoses and
Filter
Parts needed for this procedure:
g219471
2
Hose—1.9 x 61 cm (3/4 x 24 inches)
9
Hose clamp
1
T-fitting
1
Hose—1.9 x 180 cm (3/4 x 71 inches)
2
Straight-barb fitting
1
Filter assembly
1
Convoluted conduit
2
Cable tie
Install the Rinse Nozzle Hoses
Note:
Lightly lubricate the barbed end of the hose
fittings with a non-petroleum based lubricant, such as
vegetable oil, to ease the process of installation.
1.
Assemble 2 hoses—1.9 x 61 cm (3/4 x 24
inches) and 2 hose clamps onto each the 90°
fitting at the rinse nozzle assemblies, and tighten
the clamps by hand
g220000
1. Hoses—1.9 x 61 cm (3/4
x 24 inches)
2. 90° fitting
3. Hose clamp
2.
Loosely assemble the other end of the
hoses—1.9 x 61 cm (3/4 x 24 inches) on to the
T-fitting with 2 hose clamps as shown in
27.
13
(Figure
27).
Figure 27
4. T-fitting
5. Hose—1.9 x 180 cm (3/4
x 71 inches)
g206607
Figure