5
Installing the Rinse-Tank
Pump
Parts needed for this procedure:
1
Rinse-tank pump
4
Bolt (1/4 x 1-3/4 inches)
4
Washer (1/4 inch)
4
Serrated-flange nut (1/4 inch)
1
Pump cover
Assembling the Pump to the
Machine
Owner provided material: PTFE sealant
1.
Align the holes in the mounting-flange spacers
of the rinse-tank pump with the holes in the
saddle plate of the tank frame
(Figure
24).
12
Figure 24
1. Washer (1/4 inch)
2. Bolt (1/4 x 1-3/4 inches)
3. Mounting-flange
(rinse-tank pump)
2.
Assemble the rinse-tank pump to the saddle
plate
(Figure
24) with 4 bolts (1/4 x 1-3/4 inches),
4 washers (1/4 inch), and 4 serrated-flange nuts
(1/4 inch).
3.
Torque the bolts and flange nut to 1017 to 1234
N∙cm (90 to 101 in-lb).
4.
Remove the dust plug from the 2-socket
electrical connector of the machine harness
labeled R
P
INSE
UMP
4. Serrated-flange nut (1/4
inch)
5. Saddle plate (tank frame)
(Figure
25).
g206594