Connecting Power - Advantech UNO-137 V2 User Manual

Intel atom x6413e and x6425re processor automation computer, with 2 x lan, 2 x com, 4 x usb, 2 x dp, 8 xdio, 1 x mpcie, and 2 x m.2
Hide thumbs Also See for UNO-137 V2:
Table of Contents

Advertisement

2.2

Connecting Power

This product is intended to be supplied by an approved power adapter or DC power
source. This adapter is rated at 10 Vdc - 36 Vdc, 7.7 -1.31 A and has a Tmax of 70°C
(158°F). If you need further assistance or information, please contact Advantech.
Note!
It is recommended to choose a 120 W adapter when selected iDoor
expansion module(e.g. PCM-24R2PE) is installed. Recommended PN:
96PSA-A120W24T2-4.
Follow the following instructions:
1.
Insert the positive and negative wires into the V+ and V- contacts on the termi-
nal block connector.
2.
Tighten the wire-clamps' screws to prevent the DC wires from coming loose.
Take the following guidelines into consideration before wiring the device:
1.
The terminal block is suitable for 12-24 AWG (12 A). Torque value 7 lb-in. Use
copper conductors only.
2.
The temperature rating of the input connection cable should higher than 95°C
(203°F).
9
UNO-137 V2 User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uno-137-e23baUno-137-i23baUno137e23b2301-tUno137e23b2407-tUno137e23b2603-tUno137e23b2302-t ... Show all