Celeron m/ pentium m embedded automation computer with two pci slot extensions (82 pages)
Summary of Contents for Advantech UNO-137 V2
Page 1
User Manual UNO-137 V2 電腦 ® Intel Atom x6413E and x6425RE processor Automation Computer, with 2 x LAN, 2 x COM, 4 x USB, 2 x DP, 8 xDIO, 1 x mPCIe, and 2 x M.2...
Page 2
No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. The information provided in this manual is intended to be accurate and reliable.
Page 4
Product Warranty (2 years) Advantech warrants the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products that have been repaired or altered by persons other than repair personnel authorized by Advantech, or products that have been subject to misuse, abuse, accident, or improper installation.
Page 5
This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This type of cable is available from Advantech. Please contact your local supplier for ordering information.
Page 6
Before system installation, check that the items listed below are included and in good condition. If any item does not accord with the list, contact your dealer immediately. UNO-137 V2 (with din-rail mount) 1 x 2x5 Plug-in block for COM port ...
Page 7
This product is intended to be supplied by an UL certified power supply or dc source with SELV output, rated 10 Vdc, 7.7A minimum and Tma 40 degree. If you need further assistance, please contact Advantech for further information. Ensure that the voltage of the power source is correct before connecting the equipment to a power outlet.
Page 8
If the equipment is used in a manner not specified by the Advantech, the protec- tion provided by the equipment may be impaired. The equipment contains no user-serviceable parts. Do not open, Return to man- ufacturer for servicing. Do not block air ventilation holes.
Page 10
限用物質含有情況標示聲明書 Declaration of the Presence Condition of the Restricted Substances Marking 型號 (型式) :UNO-137 V2 ( 系列型號請參見手冊載明型號) 設備名稱:電腦 Equipment name Type designation (Type) 限用物質及其化學符號 Restricted substances and its chemical symbols 單元 六價鉻 多溴聯苯 多溴二苯醚 鉛 汞 鎘 Unit Hexavalent Polybrominat...
The new integrated DIN-rail mounting kit is designed to be more ruggedized and user-friendly, making it a perfect fit for control cabinets. This new UNO-137 V2 model features a ruggedized design with an industrial-grade ® Intel Atom x6413E 1.5 GHz and x6425RE 1.9 GHz processor and built-in 8 GB...
USB (Type A): 2 x USB 3.2 Gen 2, x USB 3.2 Gen 1 and 1 x USB 2.0 8-ch digital input, 8-ch digital output (isolation protection: 2500V Isolated DIO Displays 2 x DP 1.2, up to 4096 x 2160 @ 60 Hz Power Connector 1 x 2 Pin (terminal block) UNO-137 V2 User Manual...
CE, FCC, UL 61010-1, CCC, BSMI 1.3.6 Extension Kit (Optional) UNO-137 V2 features a modularized design. Advantech offers an optional 2nd stack extension kit for users to expand the functionality using an Advantech iDoor module. Table 1.6: Extension Kit (Optional)
Dimensions 35 mm x 105 mm x 150 mm (1.4 in x 4.1 in x 5.9 in) Figure 1.1 UNO-137 V2 Dimensions Figure 1.2 UNO-137 V2 Dimensions (with Optional Extension Kit) UNO-137 V2 User Manual...
Chassis Grounding The UNO-137 V2 provides good EMI protection and a stable grounding base. There is an easy-to-connect chassis grounding point. Figure 2.1 Connection Diagram Use the grounding cable (16 AWG) from the accessory bag to connect the chassis ground with the earth ground.
This product is intended to be supplied by an approved power adapter or DC power source. This adapter is rated at 10 Vdc - 36 Vdc, 7.7 -1.31 A and has a Tmax of 70°C (158°F). If you need further assistance or information, please contact Advantech. Note! It is recommended to choose a 120 W adapter when selected iDoor expansion module(e.g.
M.2 Installation (Optional) The UNO-137 V2 supports the installation of M.2 E-Key 2230 and M.2 B-Key 2242. Please refer to The UNO-137 V2 Startup Manual for installation steps. 2.3.1 Antenna Installation Install the SMA connector of the antenna cable to the antenna hole.
5 x M3x4L screws for extension kit installation. Follow the steps below for extension kit Installation: Remove 2 screws from the back cover of the UNO-137 V2. Detach the iDoor dummy cover from the iDoor extension kit. UNO-137 V2 User Manual...
Page 26
Extension Kit Installation: (1) Connect the mPCIe connector of the iDoor module onto the board of the UNO-137 V2, and fix it with the M2x4L screw from the accessory bag of the UNO-137 V2. (2) Attach the iDoor extension kit onto the UNO-137 V2 with 5 x M3x4L screws from its accessory bag.
Return the back cover of the UNO-137 with the provided screws from Step 1. 2.3.3 Base Unit: mPCIe+ mSATA (Optional) Remove 2 screws from the back cover of the UNO-137 V2. Remove the provided screws from the board. Insert the mSATA card. Secure it with the provided screws Insert grease between the back cover and aluminum column and lock back the screws.
Attach the transfer plate with 4 screws to the 2nd stack. Paste thermal pad on the aluminum column then lock the second expansion chassis with 5 screws for the first chassis. Fix the back cover with the provided screws. UNO-137 V2 User Manual...
Remote Power & Reset Settings The UNO-137 V2 supports remote power and reset functions through the DI connec- tor with the switch setting (SW8) on the motherboard. The default setting is for DI6/ DI7 functionality. If you want to configure the UNO-137 for remote control functions, configure SW8- Bit 2 to “on”, then the DI6 can be used for remote power settings, and...
The following diagram demonstrates the location of the UNO-137 V2 motherboard’s key components and internal/external connectors. Figure 3.1 Diagram of Connector Locations on UNO-137 V2 (Top Side) Figure 3.2 Diagram of Key Components Location on UNO-137 V2 (Bottom Side) UNO-137 V2 User Manual...
3.2.3 USB Connector The UNO-137 V2 features 4 x USB ports that comply with 3 x Rev 3.2, 1 x Rev 2.0 specifications. The USB connectors support plug-and-play and hot-swapping func- tionality for external devices. Additionally, this can be enabled/disabled in the BIOS menu.
3.2.5 COM Connector The UNO-137 V2 has 2 x COM RS232/422/485 ports of terminal block types. They offer transmission speeds of 50 kbps ~115.2 kbps. The default mode for both COM ports (COM 1 & COM 2)is RS-232 mode. Settings can be adjusted via an on-board switch (SW1).
~ 30 V Input Voltage (dry contact), configure SW6 to setting 1 – Logic 0: Shorted to GND – Logic 1: Open Isolation Protection: 2,500 V Over-voltage Protection: 30 V Opto-Isolator Response: 50 μs UNO-137 V2 User Manual...
Page 37
Each of the 8 isolated digital input channels accept voltages from 0 V ~ 30 V. The fol- lowing figure shows how to connect an external input source to the isolated inputs of the UNO- 137 V2. Figure 3.5 Isolated DI Wet Connection Diagram Figure 3.6 Isolated DI Dry Connection Diagram UNO-137 V2 User Manual...
(500 mA max./ch), the board's current will sink from the external voltage source. The following figure shows how to connect an external output load to the isolated outputs on the UNO-137 V2. Figure 3.7 Isolated DO Connection Diagram...
DI selection for dry/wet contact Note! *This power is from DC power inputs. *JCMOS 1: Configure the UNO-137 V2 to match the needs of your application by setting switches, The following details the switch setting definitions: 3.3.1 M.2 Connector There is one M.2 M-Key connector for M.2 cards, labeled “M2_M1” on the board.
BTR (RTC Battery): Red indicates a low RTC battery. Check the RTC battery. RUN (Programmable): Users can configure the LED indicator’s behavior through GPO signal controls. Green indicates under programming. 3.4.2 Reset Buttons Press the “reset” button to initiate a hardware reset. UNO-137 V2 User Manual...
LTE or wireless functions. Note! Please be aware of the maximum OD value of the antenna hole when selecting the antenna. Figure 3.10 Diagram of Maximum OD Value for Antenna Hole UNO-137 V2 User Manual...
In MDI and in MDI-X configuration, MDI[2]+/- corresponds MDI2- to BI_DC+/- and MDI[3]+/ - corresponds to BI_DD+/-. MDI3+ 100BASE-TX: Unused. MDI3- 10BASE-T: Unused. Table A.3: LED Left LED Right LED 100/10 Link 1000 Link 2500 Link Active Orange Green Green UNO-137 V2 User Manual...
Table A.5: USB 3.0 Connector Pin Assignments Signal Name Description VBUS Power USB 2.0 differential pair Ground for power return StdA_SSRX- SuperSpeed receiver differential pair StdA_SSRX+ GND_DRIAN Ground for signal return StdA_SSTX- SuperSpeed transmitter differential pair StdA_SSTX+ UNO-137 V2 User Manual...
This switch is used to select RS232/422/485 mode settings Default RS232 mode Bit 1 ON RS232 Mode Bit 2,3,4,5,6,7,8,9,10 OFF Bit 2,4,5 ON COM1 RS485 Mode Bit 1,3,6,7,8,9,10 OFF Bit 1,2,4,5 ON RS422 Mode Bit 3,6,7,8,9,10 OFF UNO-137 V2 User Manual...
Termination resistor setting This switch is used to select the termination resistor (120 ohm) for long Description distance transmissions or device matching Default Bit 3 off & Bit 8 off COM1 Bit 3 on COM2 Bit 8 on UNO-137 V2 User Manual...
A.10 TPM 2.0 BIOS Setting The UNO-137 V2 system supports TPM 2.0 functionality. This can be enabled or dis- abled in the BIOS menu by following the instructions provided below: Power on the UNO-137 system and press “delete” to enter the BIOS configura- tion menu.
The setup utility uses a number of menus for making changes and turning the specific features on or off. This chapter describes the basic navigation of the UNO-137 V2 setup screens. Figure A.1 Main setup screen AMI’s BIOS ROM has a built-in setup program that allows users to modify the basic...
Page 56
Highlight System Time or System Date using the keys. Enter new values through the keyboard, press the key or the keys to move between fields. The date must be entered in MM/DD/YY format. The time must be entered in HH:MM:SS format. UNO-137 V2 User Manual...
Page 57
A.11.1.3 Advanced BIOS Features Select Advanced Tab from the UNO-137 V2 setup screen to enter the advanced BIOS setup screen. You can select any of the items in the left frame of the screen, such as CPU configuration, by going to the sub menu for that item. You can display an advanced BIOS setup option by highlighting it using the keys.
Page 58
A.11.1.4 CPU Configuration Figure A.4 CPU configuration Figure A.5 CPU configuration-1 CPU Flex Ratio Overide Enable/disable CPU flex ratio programming. UNO-137 V2 User Manual...
Page 59
SMM Use Block Indication Enable/disable usage of SMM_BLOCKED MSR for MP Sync in SMI. – SMM Use SMM en-US Indication Enable/Disable usage of SMM_ENABLE MSR for MP Sync in SMI. A.11.1.5 Power & Performance Figure A.6 Power & performance UNO-137 V2 User Manual...
Page 60
Figure A.7 CPU - Power management control-1 Figure A.8 CPU - Power management control-2 UNO-137 V2 User Manual...
Page 61
Timed MWAIT Enable/Disable timed MWAIT support. Custom P-state Table Add custom P-state table EC Turbo Control Mode Enable/Disable EC turbo control mode. Energy Performance Gain Enable/Disable energy performance gain. CPU Lock Configuration UNO-137 V2 User Manual...
Page 62
GT – Power Management Control Figure A.9 GT – Power management control UNO-137 V2 User Manual...
Page 63
Maximum GT frequency limited by the user. Choose between 200 MHz (RPN) AND 750 MHz (RP0). Value beyond this range will be clipped to min/max sup- ported by the SKU. Disable Turbo GT Frequency Enabled: Disables Turbo GT frequency. Disabled: GT frequency is not limited. UNO-137 V2 User Manual...
Page 64
A.11.1.6 PCH-FW Configuration: Configure Management Engine Technology Parameters Figure A.11 PCH-FW configuration Figure A.12 PCH-FW configuration - 1 ME State When disabled, ME will be put into ME temporarily disabled mode. UNO-137 V2 User Manual...
Page 66
TCG EFI protocol and INT1A interface will not be available. Disable Block Sid Override to allow SID authentication in the TCG storage device. A.11.1.8 ACPI Settings: System ACPI Parameters Figure A.15 ACPI setting UNO-137 V2 User Manual...
Page 67
Enable or disable system’s ability to hibernate (OS/S4 sleep state). This option may not be effective with some operating systems. ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed. UNO-137 V2 User Manual...
Page 68
A.11.1.9 NCT61260 Super IO Configuration: System Super IO Chip Parameters Figure A.17 NCT61260 super IO configuration Figure A.18 NCT61260 super IO configuration-1 Serial Port 1 Configuration Set parameters of serial port 1 (COM). UNO-137 V2 User Manual...
Page 69
Serial Port 2 Configuration Set Parameters of Serial Port 2 (COMB). A.11.1.10NCT6126D HW Monitor: Monitor Hardware Status Figure A.19 H/W monitor configuration Figure A.20 H/W monitor configuration-1 PC Health Status UNO-137 V2 User Manual...
Page 70
Enable or disable system wake on alarm event. Select Fixed Time, and the sys- tem will wake on the hr::min::sec specified. Select dynamic time. The system will wake at the current time + Increase minute(s). UNO-137 V2 User Manual...
Page 71
Mass Storage Devices: USB Mass storage device emulation type. “AUTO” enumerates devices according to their media format. Optical drives are emulated as “CDROM”, drives with no media will be emulated according to a drive type. UNO-137 V2 User Manual...
Page 73
Keep IGFX enabled based on the setup options. VT-d Above 4 GB MMIO BIOS assignment Enable/Disable above 4 GB memory-mapped IO BIOS assignment. This is enabled automatically when aperture size is set to 2048 MB. UNO-137 V2 User Manual...
Page 76
Enable/Disable SATA Device. SATA Mode Selection – Determines how SATA controller(s) operate. – Aggressive LPM Support Enable PCH to aggressively enter link power state. – SATA Controller Speed Indicates the maximum speed the SATA controller can support. UNO-137 V2 User Manual...
Page 77
Restore Factory Keys – Forces system into user mode. Installs factory default Secures boot key data- bases. – Key Management Enables expert users to modify secure boot policy variables without full authentication. SQF-C4MV2-128GDEDE TCG Storage Security Configuration. UNO-137 V2 User Manual...
Page 78
Number of seconds to wait for setup activation key. 65535(0xFFFF) means indefinites waiting. – Bootup NumLock State Select the keyboard <NumLock> state. Quiet Boot – Enables or disables quiet boot option. Boot Priorities – Boot Option #1 Select the system boot order. UNO-137 V2 User Manual...
Page 79
Restore/Load default values for all the setup options. Saves as User Defaults Save the changes done so far as User defaults. Restore User Defaults Restore the user defaults t all the setup options. UEFI: USB, Partition 1 (USB) UNO-137 V2 User Manual...