Connect Ground Cable; Figure 3-19: Ac Power Terminal - Baicells Aurora243 Installation Manual

Outdoor 2x10w tdd gnodeb
Table of Contents

Advertisement

Aurora243 Outdoor 2x10W TDD gNodeB Installation Guide
AC Power Supply
Refer to the labels on the power terminal for connecting the live, neutral, and ground wires
separately to the corresponding terminals separately, and then tighten the screws.

Figure 3-19: AC Power Terminal

3. Connect the power terminal to the PWR interface in the wiring cavity.
4. The power cable lays along the slot and stretches out of the wiring cavity.
5. The other end connects to a reliable AC or DC power supply.
NOTE 1: If the outlet is indoors, place the power adaptor indoors.
NOTE 2: If the outlet is outdoors, all components should be placed in a waterproof distribution
box.
6. After the cable connection is complete in the wiring cavity, tighten the screws on the cover to
close the wiring cavity using a Phillips-head screwdriver.

3.4.7 Connect Ground Cable

3.4.7.1 Pole Grounding
Pole grounding aims to protect the equipment as much as possible from potential damage from lightning
overvoltage. However, the interfaces between the gNB and the outside world mainly include a power
system, grounding system, antenna feeder and lightning receiving device, and signal line. Therefore, any
damage caused by lightning primarily comes from the voltage difference between the equipment in the
gNB and one or more of the four interfaces. The pole grounding is shown in Figure 3-20.