Acquisition Status
Acquisition Mode
Single Frame
Multi-Frame
Continuous
Acquisition Frame Count
Acquisition Arm Cmd
Acquisition Start Cmd
Acquisition Stop Cmd
Acquisition Abort Cmd
Transfer Control
Basic
User Controlled
Transfer Mode
Continuous
Multi Block
Transfer Block Count
Transfer Queue Current
Block Count
Transfer Start
Transfer Stop
Transfer Abort
Linea GigE Series Camera
AcquisitionStatus
AcquisitionMode
SingleFrame
MultiFrame
Continuous
AcquisitionFrameCount
AcquisitionArm
AcquisitionStart
AcquisitionStop
AcquisitionAbort
TransferControlMode
Basic
UserControlled
TransferOperationMode
Continuous
MultiBlock
TransferBlockCount
transferQueueCurrentBlockCount
TransferStart
TransferStop
TransferAbort
Reads the state of the internal acquisition signal selected
using the AcquisitionStatusSelector feature.
Set the acquisition mode of the device. It defines the number
of frames to capture during an acquisition and the way the
acquisition stops.
One frame is captured for each AcquisitionStart Command.
An AcquisitionStop occurs at the end of the Active Frame.
A sequence of frames is captured for each AcquisitionStart
Command. The number of frames is specified by
AcquisitionFrameCount feature. An AcquisitionStop occurs at
the end of the Active Frame(s)
Frames are captured continuously with AcquisitionStart until
stopped with the AcquisitionStop command.
Number of frames to be acquired in MultiFrame acquisition
mode.
Arms the device before an AcquisitionStart command. This
optional command validates all the current features for
consistency and prepares the device for a fast start of the
acquisition. If not used explicitly, this command is
automatically executed at the first AcquisitionStart but will
not be repeated for subsequent ones unless a data transfer
related feature is changed in the device. (WO)
Start image capture using the currently selected acquisition
mode. The number of frames captured is specified by
AcquisitionMode feature. (WO)
Stops the Acquisition of the device at the end of the current
frame unless the triggerFrameCount feature is greater then
1. (WO)
Aborts the acquisition immediately. This will end the capture
without completing the current Frame or aborts waiting on a
trigger. If no acquisition is in progress, the command is
ignored. (WO)
Sets the method used to control the transfer.
Basic mode ensures maximum compatibility but does not
allow for control of the transfer flow.
Manual mode allows maximum control of the transfer flow.
Sets the operation mode of the transfer.
Blocks are transferred continuously until stopped with the
TransferStop command.
The transfer terminates after the transition on
TransferBlockCount or before on a user request.
Specifies the number of Data Blocks the device must stream
during the next transfer.
Returns the current number of blocks in the transfer queue.
Starts the streaming of data Block(s) to another device.
Stops the streaming of dat a Block(s) to another device.
Aborts the streaming of data Block(s) to another device.
Operational Reference • 81
1.00
Expert
1.00
Beginner
1.00
Beginner
1.00
Guru
1.00
Beginner
1.00
Beginner
1.00
Beginner
1.00
Expert
1.00
Expert
1.00
Expert
1.00
Expert
1.00
Expert
1.00
Expert
1.00
Expert

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige la-gm-08k08aLinea gige la-gm-02k08a

Table of Contents