Teledyne Linea GigE LA-GM-04K08A User Manual page 74

Monochrome cmos line scan
Table of Contents

Advertisement

Output Line Source
Off
Software Controlled
Pulse On: Start of Frame
Pulse on: Start of Line
Pulse On: Start of
Exposure
Pulse On: End of
Exposure
Pulse on: Start of
Readout
Pulse On: End of Readout
Pulse On: Valid Line
Trigger
Pulse On: Invalid Line
Trigger
Pulse On: Start of
Acquisition
Pulse On: End of
Acquisition
Pulse On: Timer 1 End
Pulse On: Timer 2 End
Pulse On: Counter 1 End
Pulse On: Counter 2 End
Pulse on: Input Line 1
Event
Pulse on: Input Line 2
Event
Pulse on: Input Line 3
Event
Pulse on: Input Line 4
Event
Pulse On: Software
Command
Frame Trigger
Frame Valid
Exposure Active
Line Valid
Smart Strobe Active
Output Line Value
Active
Inactive
Exposure Delay
72 • Operational Reference
cP_OutputLineSource
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofLine
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidLineTrigger
PulseOnInvalidLineTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnTimer1End
PulseOnTimer2End
PulseOnCounter1End
PulseOnCounter2End
PulseOnInput1
PulseOnInput2
PulseOnInput3
PulseOnInput4
PulseOnSoftwareCmd
FrameTriggerActive
FrameActive
ExposureActive
ReadoutActive
SmartStrobeActive
cP_OutputLineValue
Active
Inactive
cP_ExposureDelay
Selects which internal signal, or event driven pulse, or
software control state to output on the selected output
line.
Off
Line output is Open
The OutputLineValue feature changes the state of the
output.
Generate a pulse on the start of the Frame Active event.
Generate a pulse on the start of the Line Active
Generate a pulse on the ExposureStart event. This option
is typically used to trigger a strobe light.
Generate a pulse on the ExposureEnd event. This option is
typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the LineTrigger event.
Generate a pulse on the Invalid LineTrigger event.
Generate a pulse when the AcquisitionStart event occurs.
Generate a pulse when the AcquisitionStop event occurs.
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the TimerEnd 2 event.
Generate a pulse on the CounterEnd event.
Generate a pulse on the CounterEnd 2 event.
Generate a pulse on the Input signal 1 event.
Generate a pulse on the Input signal 2 event.
Generate a pulse on the Input signal 3 event.
Generate a pulse on the Input signal 4 event.
Generate a pulse on the Input of a Software Command
Generate a signal that is active when the frame trigger is
active
Generate a signal that is active when the Frame valid is
active
Generate a signal that is active when the Exposure is
active
Generate a signal that is active when the line valid is
active
Generate a signal that is active when the Readout or the
ExposureDelay are active. The smart strobe only works
when triggerLineCount is greater than 1
Sets the output state of the selected Line if the
outputLineSoftwareLatchControl = OFF. OutputLineSource
must be SoftwareControlled. If the
outputLineSoftwareLatchControl = Latch , the state of the
pin will change with the outputLineSoftwareCmd
command.
Sets the Output circuit to closed.
Sets the Output circuit to open.
Sets the exposure delay (in microseconds) for the selected
set.
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
Linea GigE Series Camera

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige la-gm-08k08aLinea gige la-gm-02k08a

Table of Contents