Teledyne Linea GigE LA-GM-04K08A User Manual page 58

Monochrome cmos line scan
Table of Contents

Advertisement

Flat Field Correction
Current Active Set
Factory Flatfield
User Flatfield 1
User Flatfield 2
User Flatfield 3
User Flatfield 4
Flat Field Correction Type
Line-Based
Flat Field Correction
Algorithm
Method 1
Calibration Algorithm
Basic
Low Pass Filter
Flat Field Calibration
Target
Flat Field Calibration
Sample Size
2048
4096
Flat Field Calibration
Offset X
Flat Field Calibration
Width
Calibrate FPN
No Error
Calibration Failed
Camera Busy
Timeout Error
Memory Error
Target Error
56 • Operational Reference
flatfieldCorrectionCurrentActiveSet
FactoryFlatfield
UserFlatfield1
UserFlatfield2
UserFlatfield3
UserFlatfield4
flatfieldCorrectionType
LineBase
flatfieldCorrectionAlgorithm
Method1
flatfieldCorrectionCalibrationAlgorit
hm
LowPass
flatfieldCalibrationTarget
flatfieldCalibrationSampleSize
Lines_2048
Lines_4096
flatfieldCalibrationROIOffsetX
flatfieldCalibrationROIWidth
flatfieldCalibrationFPN
NoError
GenericError
BusyError
TimeoutError
MemoryError
TargetError
Specifies the current set of Flat Field coefficients to use.
User data is uploaded via the file access feature.
Feature used when flatfieldCorrectionMode is Active. In
Calibration, changing this feature has no effect unless
you save the FFC, where this feature defines where to
save the values. This feature also can be used to copy
FFC sets.
Sets the factory Flat Field coefficient table as the current
Flat Field.
Sets User Flat Field 1 coefficient table as the current Flat
Field.
Sets User Flat Field 2 coefficient table as the current Flat
Field.
Sets User Flat Field 3 coefficient table as the current Flat
Field.
Sets User Flat Field 4 coefficient table as the current Flat
Field.
Specifies the Flat Field correction type.
Flat field correction is based on an individual line
(FlatLine).
Specifies the Flat Field correction algorithm to use.
The following formula is used to calculate the flat field
corrected pixel: newPixelValue[x] = (sensorPixelValue[x]
- FFCOffset[x]) * FFCGain[x]
Specifies the flatfield calibration algorithm to use.
Basic
Direct calculation of coefficients based on average line
values and target.
Apply a low pass filter to average line prior to calculating
coefficients. Used when target is not uniformly white or it
is not possible to defocus image.
Sets the target pixel value for the gain (PRNU)
calibration.
Set flat field calibration sample size (number of lines to
sum)
2048
4096
Sets the ROI Offset X
Sets the ROI Width
Performs Fixed Pattern Noise (FPN) calibration by
reducing to zero dark pixel current using a pixel offset.
No Error
FPN calibration failed.
The camera is busy and cannot perform the FPN
calibration.
The FPN calibration did not finished on time.
The camera cannot allocate the memory needed for FPN
calibration.
The FPN calibration was not able to reach the targets.
1.00
Beginner
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
1.00
Guru
DFNC
Linea GigE Series Camera

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige la-gm-08k08aLinea gige la-gm-02k08a

Table of Contents