Input Line Detection Level
Threshold for 3.3V LVTTL
Threshold for 5V TTL
Threshold for 12V
Threshold for 24V
Line Status
Line Inverter
Input Line Debouncing
Period
Line Electrical Termination
Disabled
Enabled
Output Line Source
Off
Software Controlled
Pulse on: Start of Frame
Pulse on: Start of Line
Pulse on: Start of Exposure
Pulse on: End of Exposure
Pulse on: Start of Readout
Pulse on: End of Readout
Pulse on: Valid Line Trigger
Pulse on: Invalid Line
Trigger
Pulse on: Start of
Acquisition
Pulse on: End of Acquisition
Pulse on: End of Timer 1
Pulse on: End of Timer 2
Pulse on: End of Counter 1
Pulse on: End of Counter 2
Pulse on: Input Line 1
Event
Pulse on: Input Line 2
Event
Linea GigE Series Camera
lineDetectionLevel
Threshold_for_3V3
Threshold_for_5V
Threshold_for_12V
Threshold_for_24V
LineStatus
False / True
LineInverter
False / True
lineDebouncingPeriod
lineElectricalTermination
Disabled
Enabled
outputLineSource
Off
SoftwareControlled
PulseOnStartofFrame
PulseOnStartofLine
PulseOnStartofExposure
PulseOnEndofExposure
PulseOnStartofReadout
PulseOnEndofReadout
PulseOnValidLineTrigger
PulseOnInvalidLineTrigger
PulseOnStartofAcquisition
PulseOnEndofAcquisition
PulseOnTimer1End
PulseOnTimer2End
PulseOnCounter1End
PulseOnCounter2End
PulseOnInput1
PulseOnInput2
Specifies the voltage threshold required to recognize a signal
transition on an input line.
A signal below 1.5V will be detected as a Logical LOW and a
signal greater than 1.5V will be detected as a Logical HIGH
on the selected input line.
A signal below 2.5V will be detected as a Logical LOW and a
signal greater than 2.5V will be detected as a Logical HIGH
on the selected input line.
A signal below 5.0V will be detected as a Logical LOW and a
signal greater than 5.0V will be detected as a Logical HIGH
on the selected input line.
A signal below 5.0V will be detected as a Logical LOW and a
signal greater than 5.0V will be detected as a Logical HIGH
on the selected input line.
Returns the current status of the selected input or output
line. (RO)
Controls whether to invert the polarity of the selected input
or output line signal.
Specifies the minimum delay before an input line voltage
transition is recognizing as a signal transition.
Controls if the electrical termination of the selected line is
enabled or disabled.
Disables electrical line termination for the selected line.
Enables electrical line termination for the selected line.
Selects which internal signal or event driven pulse or
software control state to output on the selected line. Note,
the LineMode feature must be set to Output. The List of
supported output line sources is product-specific. The
Control section
provides details and timing diagrams for the
supported trigger modes.
Line output is Open
The OutputLineValue feature changes the state of the output
Generate a pulse on the start of the Frame Active event
Generate a pulse on the start of the Line Active
Generate a pulse on the ExposureStart event. This option is
typically used to trigger a strobe light.
Generate a pulse on the ExposureEnd event. This option is
typically used to trigger a strobe light.
Generate a pulse on the ReadoutStart event.
Generate a pulse on the ReadoutEnd event.
Generate a pulse on the LineTrigger event.
Generate a pulse on the Invalid LineTrigger event.
Generate a pulse when the AcquisiontStart event occurs
Generate a pulse when the AcquisiontStop event occurs
Generate a pulse on the TimerEnd 1 event.
Generate a pulse on the TimerEnd 2 event.
Generate a pulse on the CounterEnd 1 event.
Generate a pulse on the CounterEnd 2 event.
Generate a pulse on the Input signal 1 event
Generate a pulse on the Input signal 2 event
Event
Operational Reference • 41