Teledyne Linea GigE LA-GM-04K08A User Manual page 53

Monochrome cmos line scan
Table of Contents

Advertisement

Timer Status
Timer Idle
Timer Trigger Wait
Timer Delaying
Timer Active
Timer Completed
Timer Start Source
TimerReset Cmd
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Line 1
Line 2
Line 3
Line 4
Timer 1 End
Timer 2 End
Counter 1 End
Counter 2 End
Timer Line Activation
Rising Edge
Falling Edge
Any Edge
Timer Delay
Timer Duration
Timer Value
Timer Reset
Linea GigE Series Camera
timerStatus
TimerIdle
TimerTriggerWait
TimerDelaying
TimerActive
TimerCompleted
timerStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
Timer1End
Timer2End
Counter1End
Counter2End
timerStartLineActivation
RisingEdge
FallingEdge
AnyEdge
timerDelay
timerDuration
timerValue
timerReset
Returns the current state of the timer. (RO)
The timer is idle. The CounterStartSource feature is
set to off.
The timer is waiting for a start trigger.
The timer is counting the requested delay.
The timer is counting for the specified duration.
The timer reached the TimerDuration count.
Select the trigger source to start the timer. The
Control section
provides details and timing diagrams for the
supported events.
Off
Starts with the reception of the TimerReset Icommand.
Start Timer on Acquisition Start event.
Start Timer on Acquisition End event.
Start Timer on Exposure Start event.
Start Timer on Exposure End event.
Start Timer on Readout Start event.
Start Timer on Readout End event.
Start Timer on Frame Start event.
Start Timer on a transition of I/O Line 1 event.
See Input Signals Electrical Specifications.
Start Timer on a transition of I/O Line 2 event.
Start Timer on a transition of I/O Line 3 event.
Start Timer on a transition of I/O Line 4 event.
Start Timer on Timer 1 End event.
Start Timer on Timer 2 End event.
Start Timer on Counter 1 End event.
Start Timer on Counter 2 End event.
Select the trigger activation mode which starts the timer.
Starts counter on rising edge of the selected signal.
Starts counter on falling edge of the selected signal.
Starts counter on the falling or rising edge of the
selected signal.
Sets the duration (in microseconds) of the delay to apply at
the reception of a trigger before starting the timer.
Sets the duration (in microseconds) of the timer pulse.
Reads the current value (in microseconds) of the selected
timer.
Resets the timer to 0.
Event
Operational Reference • 51
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea gige la-gm-08k08aLinea gige la-gm-02k08a

Table of Contents