Counter Start Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Line 1
Line 2
Line 3
Line 4
Timer 1 End
Timer 2 End
Counter 1 End
Counter 2 End
Counter Start Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Incremental
Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Readout Start
Readout End
Frame Start
Line 1
Line 2
Line 3
Line 4
Rotary Encoder
Internal Clock
Timer 1 End
Timer 2 End
Linea GigE Series Camera
counterStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
Timer1End
Timer2End
Counter1End
Counter2End
counterStartLineActivation
RisingEdge
FallingEdge
AnyEdge
counterIncrementalSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
ReadoutStart
ReadoutEnd
FrameStart
Line1
Line2
Line3
Line4
rotaryEncoder1
InternalClock
Timer1End
Timer2End
Select the counter start source. Counter increments from 0
to the value of the counterDuration feature.
Off
Counter is stopped.
Counter starts on the reception of the Acquisition Start
event.
Counter starts on the reception of the Acquisition End event.
Counter starts on the reception of the Exposure Start event
Counter starts on the reception of the Exposure End event.
Counter starts on the reception of the Readout Start event.
Counter starts on the reception of the Readout End event.
Counter starts on the reception of the Frame Start event.
Counter starts on the specified transitions on Line 1
See Input Signals Electrical Specifications.
Counter starts on the specified transitio ns on Line 2
Counter starts on the specified transitions on Line 3
Counter starts on the specified transitions on Line 4
Counter starts on the reception of the Timer 1 End event.
Counter starts on the reception of the Timer 2 End event.
Counter starts on the reception of the Counter 1 End event.
Counter starts on the reception of the Counter 2 End event.
Selects the activation mode of the input line trigger which
starts the counter. This is only applicable when the
counterStartSource feature selects a physical Line.
Starts counting on rising edge of the selected Line.
Starts counting on falling edge of the selected Line.
Starts counting on the falling or rising edge of the selected
Line.
Select the event source which increments the counter. The
Event Control section
provides details and timing diagrams
for the supported events.
Off
Counter is stopped.
Counts the number of Acquisition Start events.
Counts the number of Acquisition End events.
Counts the number of Exposure Start events.
Counts the number of Exposure End events.
Counts the number of Readout Start events.
Counts the number of Readout End events.
Counts the number of Frame Start events.
Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting)
See Input Signals Electrical Specifications.
Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting)
Counts the number of transitions on Line 3 (based on the
counterIncrementalLineActivation feature setting)
Counts the number of transitions on Line 4 (based on the
counterIncrementalLineActivation feature setting)
The counter increments on rotary encoder ticks.
The counter increments on each microsecond tick of the
device internal Clock.
Counts the number of Timer 1 End events.
Counts the number of Timer 2 End events.
Operational Reference • 49
1.10
Expert
DFNC
1.00
Expert
DFNC
1.00
Expert
DFNC