Connectable B7A Link Terminals
Only 16-point B7A Link Terminals can be connected to a B7A Interface Unit. These are listed in the following
tables.
Input Terminals
Type
Screw terminals
Modular
PC connectors
Output Terminals
Type
Screw terminals
Modular
PC connectors
Note 1. Do not connect Terminals with different transmission delays to the same Interface Unit. Doing so will
cause a transmission error.
2. B7A Link Terminals with 10-points and B7A Link Terminals with mixed I/O (8 inputs/8 outputs) cannot be
connected to B7A Interface Units. Use 16-point B7A Link Terminals. 16-point B7A Link Terminals
include 16-point (input or output) models, models with 2 circuits configured with 16 points, and models
with 16 points of mixed I/O.
Comparison between Standard and Group-2 B7A Interface Units
Type
Models
yp
Standard
C200H-B7AI1
C200H-B7AO2
Group-2
C200H-B7A12
C200H-B7A02
C200H-B7A21
C200H-B7A22
Note In the case of Group-2 B7A Interface Units, words 030 to 049 (Group-2 High-density I/O Unit and B7A Inter-
face Unit Area) are allocated according to the setting of the I/O number setting switch on the front of the Unit
as shown in the following table. For mixed I/O Units, words are allocated in in the order output → input.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Model
B7A-T6j1
B7AS-T6j1
B7A-T6j6
B7AS-T6j6
B7A-T6D2
B7A-T6D7
B7A-TjE3
B7A-TjE8
Model
B7A-R6jj1
B7AS-R6jj1
B7A-R6jj6
B7AS-R6jj6
B7A-R6A52
B7A-R6A57
B7A-RjAj3
B7A-RjAj8
Word allocations
Same as I/O Units (in order
mounted)
mounted).
Words 030 to 049 allocated
according to I/O number setting
according to I/O number setting
(same as Group-2 High-density I/O
(same as Group 2 High density I/O
Units; see note below)
Transmission delay
Standard (19.2 ms)
(
)
High-speed (3 ms)
g
p
(
)
Standard (19.2 ms)
High-speed (3 ms)
Standard (19.2 ms)
High-speed (3 ms)
Transmission delay
Standard (19.2 ms)
(
)
High-speed (3 ms)
g
p
(
)
Standard (19.2 ms)
High-speed (3 ms)
Standard (19.2 ms)
High-speed (3 ms)
Connectable B7A Link Terminals
Transmission
Transmission
delay
Standard
Input status
types only
types only
held
held
(19.2 ms)
automatically
Standard
Switch setting
(19 2 ms) and
(19.2 ms) and
to hold or
to hold or
high-speed
high speed
reset Input
reset Input
(3 ms) types
status.
(set via
(set via
switch)
Appendix B
Points
errors
16-point
Terminals only
Terminals only
(
(10-point,
p
32-point, and
32
i t
d
mixed I/O
mixed I/O
Terminals cannot
be connected
be connected.
205