Wiring Settings (Wiring Menu)

When configuring a system in which the switcher inputs and outputs are
connected to a router, setting this connection configuration (referred to as
"wiring") in the S-Bus space, or inputting the information which specifies the
physical wiring, is necessary.
To make the wiring settings, use the Router/Tally >Wiring menu. The settings
are common to the parallel and serial tallies.
To display the Wiring menu
In the Engineering Setup menu, select VF6 'Router/Tally' and HF3 'Wiring.'
The status area shows the wiring settings.

Making New Wiring Settings

1
In the Router/Tally >Wiring menu, press [New].
The New menu appears.
2
With a knob or menu operation, set the destination.
When switcher inputs and outputs are connected to the router in a group,
you can specify the start and end destination addresses.
Destination From: Specify the start destination address for the wiring
configuration.
Destination To: When the wiring configuration is multiple, specify the
end destination address. For a single wiring connection, this setting is
not required.
Destination Level: Specify the destination level of the wiring
configuration.
Knob
1
2
3
3
Set the source.
Source From: Specify the source start address for the wiring
configuration.
Parameter
Adjustment
Destination (From)
Destination start address 1 to 1024
Destination (To)
Destination end address
Destination (Level)
Destination level
Setting values
From start address to
1024
1 to 8
Wiring Settings (Wiring Menu)