Rklf Scale Specifications - Renishaw ATOM RTLF Series Installation Manual

Linear encoder system
Table of Contents

Advertisement

RKLF scale specifications

Material
Form (height × width)
Scale pitch
Reference mark
Accuracy (at 20 °C)
Coefficient of thermal expansion (at 20 °C)
Length
Mass
End fixing
1
Maximum recommended axis length 1 m for 20 μm systems.
2
The scale and end clamps must be installed following the installation process, see page
Hardened and tempered martensitic stainless steel fitted with a self-adhesive backing tape
0.15 mm × 6 mm (including adhesive)
20 μm and 40 μm
Auto-phase optical reference mark repeatable to unit of resolution throughout specified speed and temperature range
Customer de-selectable reference marks at 50 mm spacing
Reference mark in the centre of scale for lengths < 100 mm
RKLF20-S / RKLF40H-S
±5 μm/m
RKLF40-S
±15 μm/m
Matches that of substrate material when scale ends fixed by epoxy mounted end clamp
20 mm to 1 m in 10 mm increments
1 m to 10 m in 1 m increments
4.6 g/m
Epoxy mounted end clamps (A-9523-4015)
RGG-2 two part epoxy adhesive (A-9531-0342)
Scale end movement typically < 1 μm
17
and page 20.
1
2
www.renishaw.com
75