Linear encoder system
Table of Contents

Advertisement

Cable variant
Ferrule
A
Cable interboard connector
1
Detail A
Cable
interboard
connector
1
Ensure suitable clamping to retain interboard connector on ACi.
30
ATOM linear encoder system
JST output
connector
2 mounting holes
M3 through
PCB
Shielding
For optimum performance:
Ensure 100% shielding
Ground the mounting brackets
Use a metal clamp around the cable ferrule to ground the readhead cable
Ensure continuity of all shields
Maximise the distance between the encoder and motor cables
Provide appropriate strain relief at the readhead and interface
The ACi should be contained within a shielded enclosure
Ensure suitable clamping to retain interboard connector to the mating connector
Mounting
The ACi can be mounted to customers' system using two M3 screws or two M2.5 screws for through mounting.
Output
The output connector is a 10-way JST, GH crimp connector with 1.25 mm pitch. It is suitable for cable
size 26 to 30 AWG. See page
58
for pin-out information.
Approved ESD precautions must be followed at all times during readhead
and interface electrical connection.