Working with program levels
Overview
The following figure shows an overview of the welding parameter settings in the program
level preferences, using the MagicWave control panel as an example. A detailed descrip-
tion of these settings can be found in the following chapters.
1.
2.
3.
4.
5.
56
(3)
(5)
Setup parameters for rod electrode:
Hti ...... Hot current time
HCU ... HotStart current
dYn .... Dynamic correction
PRO ... Save program
FAC ... Reset welding system
Mode button
Process button
TIG welding parameters:
GAS... Gas pre-flow
G-L .... Gas post-flow at minimum welding current
G-H.... Gas post-flow at maximum welding current
UPS... UpSlope
SCU... Starting current in % of IH
I3 ....... Lowering current
HFt .... High frequency
SCU... Starting current rel/abs
StS..... Special 2-step mode
SFS ... Special 4-step mode
C-C.... Cooling unit control
E-S .... Power source shutdown
PRO ... Save program
FAC ... reset
TIG AC:
like operating mode TIG DC
(4)
(1)