Vent Restrictor Installation

1. Determine the venting configuration.
Note: The Set 1/Set 2 vent restrictor plate is installed from the factory to
Set 1 (2" open). Set 3 uses a separate restrictor plate, which is found
in the manual package.
2. Go to venting arrangements section (in the manual) to determine if
a vent restrictor setting is required. (If required, proceed to Step 3).
3. Loosen the two screws that secure the top heat deflector and remove
top heat deflector (diagram 1).
4. Align the vent restrictor plate to the required vent restrictor position as
per the Diagrams shown.
5. Once the vent restrictor plate is in the required position, secure with 2 -
1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten.
Restrictor plate for Set 1, Set 2
(Part # 761-060F)
Set 0
Fully Open
Set 2
1-3/4" Open
Restrictor plate for Set 3
(Part # 761-143F)
Set 1
2" Open
Factory Setting
Set 3
1-1/4" Open
Diagram 1: Top heat deflector
Diagram 2: Vent restrictor located on top exhaust assembly

Venting Introduction

The G800EC uses the "balanced flue" technology Co-Axial system. The
inner liner vents products of combustion to the outside while the outer liner
draws outside combustion air into the combustion chamber thereby elimi-
nating the need to use heated room air for combustion and losing warm
room air up the chimney.
Note: These flue pipes must not be connected to any other
appliance.
The gas appliance and vent system must be vented directly to the outside
of the building, and never be attached to a chimney serving a separate
solid fuel or gas burning appliance. Each direct vent gas appliance must use
it's own separate vent system. Common vent systems are prohibited.