5.2 Specifications

See the specifications in the following tables for:
Enphase IQ7-60-2-US Microinverters
Enphase IQ7PLUS-72-2-US Microinverters
Enphase IQ7X-96-2-US Microinverters
Enphase IQ7A-72-2-US Microinverters
IQ Cable

5.2.1 IQ7-60-2-US Microinverter specifications

Topic
Commonly used module pairings
Peak power tracking voltage
Operating voltage range
Maximum input DC voltage
Minimum/Maximum start voltage
Maximum DC input short circuit current (module Isc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
AC Parameters
Maximum continuous AC output power (-40°F to
+149°F)
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
240 VAC (single phase)
208 VAC (single phase)
Nominal output current
240 VAC (single phase)
208 VAC (single phase)
Nominal frequency
1
No enforced DC/AC ratio. See the compatibility calculator at
compatibility
Nominal Voltage Range can be extended if required by the utility.
2
32
IQ7/IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual
Enphase IQ7-60-2-US Microinverter parameters
DC Parameters
1
2
© 2023 Enphase Energy Inc. All rights reserved.
Unit
V
V
V
V
A
A
1x1 ungrounded array; no additional DC side protection required;
AC side protection requires max 20 A per branch circuit
VA
VA
Vrms
Vrms
Arms
Arms
Hz
enphase.com/en-us/support/module-
Min
Typical
235 W – 350+ W
27
16
22
II
240
250
0.85 leading ...0.85 lagging
211
183
1.0
1.15
60
September 2023
IOM-00028-1.0
Max
37
48
48
48
15
0
264
229