Specifications - enphase IQ8P Installation And Operation Manual

Microinverters
Hide thumbs Also See for IQ8P:
Table of Contents

Advertisement

Specifications

See the specifications in the following tables:
IQ8P-72-2-US Microinverters
IQ Cable
INPUT DATA (DC)
Typical module
compatibility
Minimum/Maximum
input voltage
Start-up input
voltage
Minimum/Maximum
MPP voltage
Minimum/Maximum
operating voltage
Maximum input
current
Maximum short-
circuit DC input
current
Maximum module Isc
Maximum input
power
1
OUTPUT DATA (AC)
Maximum apparent
power
Rated power
Nominal grid voltage
Minimum/Maximum
grid voltage
Maximum output
current
Nominal frequency
29
NOTATION
UNITS
U
/U
V
dcmin
dcmax
U
V
dcstart
U
/U
V
mppmin
mppmax
U
/U
V
opmin
opmax
I
A
dcmax
I
A
scmax
I
A
scmax
P
W
dcmax
S
VA
ac, max
P
W
ac, r
U
V
acnom
U
/U
V
acmin
acmax
I
A
acmax
f
Hz
nom
© 2024 Enphase Energy Inc. All rights reserved.
IQ8P-72-2-US
60-cell/120-half-cell, 66-cell/132-half-cell, 72-
cell/144- half-cell, 78-cell/156-half-cell
No enforced DC/AC ratio and maximum input
power. Modules can be paired if the maximum input
voltage is not exceeded and the maximum input
current of the inverter at the lowest and highest
temperatures is respected. See the compatibility
calculator at
https:/ /enphase.com/en-
ph/installers/microinverters/calculator.
16/65
22
36/55
16/65
14
25
20
640
480
475
240/220
184/276
2.00/2.18
60
Enphase IQ8P Microinverters
January 2024
IOM-00002-1.0

Advertisement