Manufacturer's Stated Accuracy; Specifications - enphase IQ7 Installation And Operation Manual

Microinverters for ac module applications
Table of Contents

Advertisement

NOTE: Only an authorized installer, following the requirements of the local electrical utility, is allowed
to make grid profile adjustments.
NOTE: Grid profile changes are applied only after a microinverter is detected.
In some regions and situations, microinverter trip points may be adjusted to account for high grid voltage or
local conditions.
Grid profile management tasks include:
• Set the grid profile for your region
• View or verify current trip point settings
• Generate a report for confirmation of site settings to the utility or other authority
To modify the grid profile or the parameters within the grid profile, installers must log in to their Enphase App
account using their credentials.
The following tables show the parameter settings for the grid profiles available for IQ7 Series International
Microinverters:
NOTE: Simultaneous use of fixed power factor and Volt/VAr is not supported.

Manufacturer's stated accuracy

Measurement
Volts
Amps
Watts
VAr
Displacement power factor
Hz
Time

Specifications

See the specifications in the following tables:
IQ7-60-ACM-INT
IQ7PLUS-72-ACM-INT, IQ7PLUS-72-E-ACM-INT
IQ7X-96-ACM-INT
IQ7A-72-E-ACM-INT
26
Default tolerance of measurement
± 1%
±2%
± 5%
± 3%
±2%
± 0.1 Hz
The greater of ± 2 cycles or 0.1% of the total
clearing time
© 2023 Enphase Energy Inc. All rights reserved.
IQ Microinverters for AC Module applications
June 2023
USM-00001-1.0