Topic
Compatibility
Dimensions not including mounting bracket
Connector type
Weight
Environmental category/UV exposure rating
Torque specifications for fasteners
(Do not over torque)
Cooling
Relative humidity range
Approved for wet locations
Pollution degree
Communication
Standard warranty term
Compliance
Grounding
Monitoring
Integrated DC disconnect/
Integrated AC disconnect
41
IQ7/IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual
IQ7A-72-2-US Microinverter parameters
Unit
Features and specifications
Pairs with most 60-cell/120- half-cell and 72-cell/144-half-
NEMA type 6/outdoor
6 mm (1/4") mounting hardware: 5 N m (45 – 50 in-lbs.)
8 mm (5/16") mounting hardware: 9 N m (80 – 85 in-lbs.)
When using UL 2703 mounting hardware, use the
manufacturer's recommended torque value
Natural convection - no fans
4% to 100% condensing
Yes
PD3
Power line communication (PLC)
enphase.com/warranty
CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15
Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and
conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-
2015 Rule 64-218 Rapid Shutdown of PV Systems for AC and DC
conductors, when installed according to manufacturer's instructions.
The DC circuit meets the requirements for ungrounded PV arrays
in NEC. Ground fault protection (GFP) is integrated into the class
II double-insulated microinverter.
Enphase Installer Portal monitoring options require an Enphase
IQ Gateway.
The DC and AC connectors have been evaluated and approved
for use as the load-break disconnect required by NEC 690.
© 2023 Enphase Energy Inc. All rights reserved.
Min
cell PV modules
212 mm x 175 mm x 30.2 mm (approximate)
MC-4 connector
1.08 kg (2.38 lbs.)
Typical
Max
September 2023
IOM-00028-1.0