12. Place a new wiper back. Put the left side in first and click the right side into the holder. Make sure
the wiper is fully clicked into the holder.
13. Clean the matrix plate. For more information, see
NOTE
Perform the action from step 3, do not exit the 'Clean the wiper' window.
14. Dispose the gloves as chemical waste according to local regulations.
15. Close all covers.
16. On the operator panel, tap on [Replaced] to end the maintenance action.
The counter will be reset.
Clean the matrix plate area on page
Chapter 6 - Maintain the system
Replace the wiper
182.
213