4. Open the media cover (1) and lift the lever of the manual maintenance door on the left (2).
5. Open the manual maintenance door (3). A light is switched on.
IMPORTANT
Do not use any external light source to prevent curing of the ink and damage to the
printheads.
6. Locate the M&C scanner (indicated by the yellow circle) next to the matrix plate in the
compartment.
7. Dampen a lint free cloth with the cleaner IPA and clean then glass plate in front of the M&C
scanner.
IMPORTANT
Only clean the glass plate of the M&C scanner. Do not touch the nozzle areas of the
printhead. When you touch the nozzle areas you can damage the printhead.
IMPORTANT
Use the prescribed cleaning liquid. Do not use any other cleaners.
IMPORTANT
This cleaning liquid (IPA) is not used for cleaning the matrix plate, wiper and clean
wall, maintenance drawer and heated parts of the maintenance station.
Clean the M&C scanner
Chapter 6 - Maintain the system