Replacing A Hot-Plug Psu - Fujitsu PRIMERGY RX4770 M5 Upgrade And Maintenance Manual

Table of Contents

Advertisement

If a hot-plug PSU should be removed from a redundant configuration,
while the system is in operation, proceed the following:
Disconnect the power cord from the dedicated PSU, see
"Disconnecting the power cord" on page
A CSS error is detected and the message "redundancy lost" is displayed
using the iRMC web interface. Your configuration is now non-redundant.
The CSS error is only an information. After removing the PSU out of its
bay, the CSS error will be cleared automatically.
Concluding steps
▶ No steps needed.
6.3.3

Replacing a hot-plug PSU

Customer Replaceable
Unit (CRU)
Tools:
tool-less
Preliminary steps
"Locating the defective server" on page
"Locating the defective component" on page
▶ Check which PSU is defective.
A PSU is defective when the PSU status indicator lights orange. For more
information, see
▶ Remove the power cord from the defective PSU, see
power cord" on page
Note for servers using CMA (Cable Management Arm)
Regarding of removing PSUs, additional tasks are needed, due to an
interference between CMA stopper and the PSUs.
RX4770 M5
"Indicator on hot-plug PSU" on page
46.
Upgrade and Maintenance Manual
Power supply unit (PSU)
46.
Hardware: 5 minutes
43.
44.
429.
"Disconnecting the
129

Advertisement

Table of Contents
loading