12.3

Dimensioned drawings

all dimensions in mm
A
2 integrated LEDs for illumination (red light)
B
1 integrated target LED (blue light)
C
Center of optical axis
D
HIROSE (FH33-125-0.5SH(10)), 12-pin
E
Mounting tabs, optional
Fig. 12.2:
DCR 40 dimensioned drawing
NOTICE
It is advisable to use a transparent, double-sided anti-reflective coated material when installing
the scan engine behind a pane of glass. Recommended pane thickness: 1 mm; optics as flush
as possible with the glass.
Leuze electronic
DCR 40
Technical data