Code Description
QR Code – Mode 1
QR Code – Custom
Straight 2 of 5
Telepen – Get All Pa-
rameter
Telepen
Telepen – Ouput ASCII
Trioptic – Get All Param-
eter
Trioptic
Trioptic – Reverse
Leuze electronic
Command Format Op-
tions
SY
QRC
S/P/R/
M1
O
G
SY
QRC
S/P/R/
CQ
O
G
SY
S2O
S/P/R/
EN
5
G
SY
TELP G
SY
TELP S/P/R/
EN
G
SY
TELP S/P/R/
OA
G
SY
TRIO G
SY
TRIO S/P/R/
EN
G
SY
TRIO S/P/R/
RV
G
DCR 40
De-
Notes/Examples
fault
0
0
Disable
Example: SYQRCOSM10
1
Enable
Example: SYQRCOSM11
Note: This setting value is ignored if QR
Code decoding is disabled.
0
0
Disable
Example: SYQRCOSCQ0
1
Enable
Example: SYQRCOSCQ1
Note: This setting value is ignored if QR
Code decoding is disabled.
0
0
Disable
Example: SYS2O5SEN0
1
Enable
Example: SYS2O5SEN1
Returns all Telepen parameter values in
an XML element.
Example: SYTELPG
0
0
Disable
Example: SYTELPSEN0
1
Enable
Example: SYTELPSEN1
0
0
Disable
Example: SYTELPSOA0
1
Enable
Example: SYTELPSOA1
Note: This setting value is ignored if
Telepen decoding is disabled.
Returns all Trioptic parameter values in
an XML element.
Example: SYTRIOG
0
0
Disable
Example: SYTRIOSEN0
1
Enable
Example: SYTRIOSEN1
0
0
Disable
Example: SYTRIOSRV0
1
Enable
Example: SYTRIOSRV1
Note: This setting value is ignored if Tri-
optic decoding is disabled.
Configuration control