Reader Configuration; General Firmware Operation - Leuze electronic DCR 40 Original Operating Instructions

Scan engine
Table of Contents

Advertisement

Code Description
RDCMXPL
Reader Command to set a
platform configuration
Get All Reader Licenses
Load License
Delete License
8.2.8

Reader configuration

Code Description
Get All Reader Parameters
Reset Reader to Factory
Default
8.2.9

General firmware operation

Code Description
Get All Firmware Parame-
ters
Leuze electronic
Command Format Op-
tions
"<Configuration>"
RD LC
G
GL
RD LC
X
LD
RD LC
X
DL
Command Format Op-
tions
CF
G
CF
R
Command Format Op-
tions
FW FW
G
DCR 40
De-
Notes/Examples
fault
Quoted string containing the Configuration Con-
trol Command. The configuration will be saved
and restored on reboot/restart. Enclose the com-
mand in square brackets (inside the quotes) and
add a carret between the opening square bracket
and command to delete a command from the
platform configuration
Save Example:
RDCMXPL"FBGRPBI1"
Delete Example:
RDCMXPL"[^FBGRPBI1]"
Returns all Reader License values in an
XML element.
Example: RDLCGGL
"URL
Loads license on the reader
en-
Copies the contents of the License CRB
coded
file starting after the '?'character to use
license
as the URL encoded license string. This
string"
string must be in quotes in the com-
mand.
Example: RDLCXLD"%23%45...."
Li-
Deletes a license
cense
License number is an integer that repre-
num-
sents just the license number, not the
ber
serial number of the license you want to
delete.
Example: RDLCXDL5000
De-
Notes/Examples
fault
Returns all Reader Parameter values in
an XML element.
Example: CFG
Resets all reader parameters to factory
default values.
Example: CFR
De-
Notes/Examples
fault
Returns all Firmware parameter values
in an XML element.
Example: FWFWG
Configuration control
53

Advertisement

Table of Contents
loading

Table of Contents