Trigger - In; Switching Output - Leuze electronic DCR 40 Original Operating Instructions

Scan engine
Table of Contents

Advertisement

5.3.5

TRIGGER - In

The TRIGGER line activates the device.
Ä Pull the TRIGGER line LOW to activate the device.
3.3 V DC
2.2 k
GND
Connection version NPN: standard setting (LOW= active)
Fig. 5.1:
Wiring example of the TRIGGER input
5.3.6

Switching output

The NPN switching output connection between switching output (pin 10) and GND (pin 3) switches if a
code is detected against GND.
3.3 V DC
3.3 V DC
max. 20 mA !
GND
Fig. 5.2:
Switching output
NOTICE
Maximum loading of the switching output
Ä Do not load the switching output of the scan engine with more than 20 mA at 3.3 ... V DC!
Leuze electronic
3.3 V DC
2
TRIGGER
12
GND
3
3.3 V DC
2
R
L
OUT
10
GND
3
DCR 40
Electrical connection