Leuze electronic DCR 40 Original Operating Instructions page 33

Scan engine
Table of Contents

Advertisement

Code Description
Korean Post
Matrix 2 of 5
Maxicode
MSI Plessey – Get All
Parameter
MSI Plessey
MSI Plessey – Require
Checksum
MSI Plessey – Strip
Checksum
Plessey – PLE
NEC 2 of 5 – Get All Pa-
rameter
Leuze electronic
Command Format Op-
tions
SY
KOP
S/P/R/
EN
O
G
SY
M2O
S/P/R/
EN
5
G
SY
MAX
S/P/R/
EN
C
G
SY
MSIP G
SY
MSIP S/P/R/
EN
G
SY
MSIP S/P/R/
CS
G
SY
MSIP S/P/R/
SC
G
SY
MSIP S/P/R/
PE
G
SY
N2O
G
5
DCR 40
De-
Notes/Examples
fault
0
0
Disable
Example: SYKOPOSEN0
1
Enable
Example: SYKOPOSEN1
0
0
Disable
Example: SYM2O5SEN0
1
Enable
Example: SYM2O5SEN1
0
0
Disable
Example: SYMAXCSEN0
1
Enable
Example: SYMAXCSEN1
Returns all MSI Plessey parameter values
in an XML element.
Example: SYMSIPG
0
0
Disable
Example: SYMSIPSEN0
1
Enable
Example: SYMSIPSEN1
0
0
Disable
Example: SYMSIPSCS0
1
Enable
Example: SYMSIPSCS1
2
10/10 Checksum type
Example: SYMSIPSCS2
3
11/10 Checksum type
Example: SYMSIPSCS3
Note: This setting value is ignored if MSI
Plessey decoding is disabled.
0
0
Disable
Example: SYMSIPSSC0
1
Enable
Example: SYMSIPSSC1
Note: This setting value is ignored if MSI
Plessey decoding is disabled.
0
0
Disable
Example: SYMSIPSPE0
1
Enable
Example: SYMSIPSPE1
Returns all NEC 2 of 5 parameter values
in an XML element.
Example: SYN2O5G
Configuration control
34

Advertisement

Table of Contents
loading