Code Description
Initial gain
Minimum lightest pixel value MD PM
Maximum lightest pixel
value
Detection pixel threshold
Detection total threshold
Detection blob threshold
Leuze electronic
Command Format Op-
tions
MD PM
S/P/R/
IG
G
S/P/R/
NL
G
MD PM
S/P/R/
XL
G
MD PM
S/P/R/
PL
G
MD PM
S/P/R/
TL
G
MD PM
S/P/R/
BT
G
DCR 40
De-
Notes/Examples
fault
21
Valid Range: Minimum Gain to Maxi-
mum Gain
Example: MDPMSIG15
60
0
Minimum Value
Valid Range: 0 to Maximum lightest
pixel value
Example: MDPMSNL60
90
255
Maximum Value
The lightest values give the motion cal-
culations a base range for maximum
brightness before the image begins to
saturate. If you set these too high, the
algorithm will not be able to detect indi-
vidual pixels because the image is
washed out.
Valid Range: Minimum lightest pixel
value to 255
Example: MDPMSXL90
15
This pixel threshold is the minimum dif-
ference value between the background
brightness and the pixel brightness for
the current pixel to be considered a
pixel.
Valid Range:
Example: MDPMS PL15
5
Total threshold is the minimum number
of pixels detected per detection region
(left, center, right) to be considered de-
tected motion
Valid Range:
Example: MDPMS TL5
4
The minimum number of sequential pix-
els to be considered a group or blob
(like a bar width)
Valid Range:
Example: MDPMSBT4