7.8
Connect the control cable for the tilt sensors to the power
cabinet (option)
Preliminary requirements
Procedure
1. Strip the insulation from the ends
of the wires (A) to (H). For the
specification, refer to section 12.19.7.
2. Crimp ferrules onto the end of the
wires.
3. Loosen the screws of the terminal
block X-1.
4. Connect these wires:
5. Tighten the screws to the correct torque. For the specification, refer to section
12.14.
9AKK107992A2254-EN | 005
Torque screwdriver, cross
Wire cutter
Wire stripper pliers
Crimp pliers
V+ wire (A) from the external
customer interface, wire number 1,
to the terminal X1-1 (I)
V- wire (C) from the external
customer interface, wire number 2,
to the terminal X1-3 (K)
Rin wire (E) from the external customer interface, wire number 3, to the
terminal X1-5 (M)
Rout wire (G) from the external customer interface, wire number 4, to the
terminal X1-7 (O)
Electrical installation of the power cabinet
Control cable for the tilt
sensors. Refer to section
12.19.7.
Ferrules
I J K L M N
D
C
B
A
O
P
H
G
F