Remove The Cable Gland Plates; Install The Charge Post On The Foundation - ABB Terra HP Generation 3 CE Instruction Manual

175 kw static dc system
Table of Contents

Advertisement

6.3.2

Remove the cable gland plates

Preliminary requirements
Procedure
1. Remove these parts:
a. Fasteners (A)
b. Cable gland plates (B)
c. Nuts (C) of the cable glands
6.3.3

Install the charge post on the foundation

Preliminary requirements
Procedure
1. Carefully lower the charge post on the
foundation with a hoisting equipment
or a forklift truck. Refer to section 12.3.
2. Make sure that the holes in the charge
post (A) and the foundation (B) are
aligned.
3. Install the fasteners (C) and the
washers.
4. Tighten the fasteners to the correct
torque. For the specification, refer to
section 12.14.
9AKK107992A2254-EN | 005
The door is open.
The protection cover is
removed.
Hoisting equipment or
forklift truck
Torque wrench
Caution: Make sure that
there is no kink in the
cables.
Installation
Screwdriver, cross
Set of open spanners
A
B
C
Six fasteners M12 and
washers
Drop in anchors, for easy
installation and quality
C
A
B
41

Advertisement

Table of Contents
loading

Table of Contents