Section 3 - Controls and Indicators

Load Stability Indicator - LSI

TIP OVER HAZARD. The LSI considers only longitudinal stability limitations, observe
all operating parameters. Failure to follow operating parameters of the telehandler
could damage the equipment and/or cause tip over.
Prior to SN E160000141 excluding E160000120, E160000126,
1160008774, 1160008775 & 1160008777
The LSI (1) provides visual and audible indication of forward stability limitations when
machine is static on firm, level surface.
• Green LED (2) will illuminate when LSI power is on.
• When approaching forward stability limitations LEDs progressively illuminate, green
(3), then orange (4) and finally red (5).
• If the red LED illuminates the warning buzzer also sounds.
• As the telehandler reaches forward stability limitations and the red LED (5) illuminates,
the automatic function cut-out is activated. All boom, frame level and outrigger
functions are disabled except for boom retract (CE & AUS) and boom lift (CE). Retract
boom to re-enable functions.
• In some instances the LSI system may slow down or stop boom functions if operated
close to forward stability limitations. When LEDs begin to flash, certain functions can
not be operated.