Section 5 - Attachments & Hitches
Hydraulic Operated Attachment
1. Install attachment (see page 5-10, 5-12 or 5-14).
2. Lower attachment to ground.
3. Quickly depress and release the continuous auxiliary hydraulics switch (1) twice.
Immediately depress again and hold at least one second to relieve pressure at both
auxiliary fittings (2).
Note: Depressing the continuous auxiliary hydraulics switch three times must be
accomplished within two seconds. Buzzer will sound while auxiliary decompression is in
progress.
4. Perform "Shut-Down Procedure" on page 4-3.
5. Connect attachment hoses to both auxiliary fittings.
5-16
1
OZ4200
2
OZ4411
31200938