Section 7 - Lubrication and Maintenance
Hydraulic Oil
A. Hydraulic Oil Level Check
1. Be sure all cylinders are fully retracted, outriggers are fully raised and machine is
level.
2. Perform "Shut-Down Procedure" on page 4-3.
3. If hydraulic oil is cold, check fluid level at the sight gauge (1) on the hydraulic tank (2).
The oil level should be visible in the gauge window.
4. If hydraulic oil is low, unlock and open access panel (3).
5. Remove fill cap (4). Add fluid to bring oil up to the center of the sight gauge.
6. Replace hydraulic oil fill cap.
7. Close and secure access panel.
7-16
3
2
10
OW0970
4
1
OW1030
OZ4070