Status
Battery over
discharged
Battery over
voltage
Battery over
temperature
Controller over
temperature
System voltage
error

3.4 Setting

(1)Clear the generated energy
Operating:
Step 1: Press the "ENTER" button and hold 5s under the PV power interface and the value is
flashing.
Step 2: Press the "ENTER" button to clear the generated energy.
(2)Switch the battery temperature unit
Press the "ENTER" button and hold 5s under the battery temperature interface.
(3)Battery type
Support battery types
1
Lead-acid battery
2
Lithium battery
Setting the battery type via the LCD
www.solarv.de
Fault
charging
indicator
indicator
Red
——
on solid
Red
——
slowly
flashing
Red
——
slowly
flashing
Red
Green
slowly
slowly flashing
flashing
Red
Green
slowly
fast flashing
flashing
Icon
Sealed(default)
Gel
Flooded
User
LiFePO
(4S/12V;8S/24V;16S/48V)
4
Li(NiCoMn)O
(3S/12V;6S/24V;12S/48V)
2
User
18
Copyright © 2020 SolarV GmbH All rights reserved
Description
Battery level shows empty,
battery frame blink, fault icon
blink.
Battery
level
shows
battery frame blink, fault icon
blink.
Battery level shows current
value, battery frame blink,
fault icon blink.
Battery level shows current
value, battery frame blink,
fault icon blink.
Battery level shows current
value, battery frame blink,
fault icon blink.
full,